Toward Standardized Performance Evaluation of Flow-Guided Nanoscale Localization

Nanoscale devices with Terahertz (THz) communication capabilities are envisioned to be deployed within human bloodstreams. Such devices will enable fine-grained sensing-based applications for detecting early indications (i.e., biomarkers) of various health conditions, as well as actuation-based ones such as targeted drug delivery. Associating the locations of such events with the events themselves would provide an additional utility for precision diagnostics and treatment. This vision yielded a new class of in-body localization coined under the term “flow-guided nanoscale localization”. Such localization can be piggybacked on THz communication for detecting body regions in which biological events were localized with the traveling time reported by nanodevices flowing with the bloodstream. From decades of research on objective benchmarking of “traditional” indoor localization and its eventual standardization (e.g., ISO/IEC18305:2016), we know that in early stages, the reported performance results were often incomplete (e.g., targeting a subset of relevant performance metrics). Reported results in the literature carried out benchmarking experiments in different evaluation environments and scenarios and utilized inconsistent performance indicators. To avoid such a “lock-in” in flowguided localization, we propose a workflow for standardized performance evaluation of such approaches. The workflow is implemented in the form of an open-source simulation framework that is able to jointly account for the mobility of the nanodevices, in-body THz communication with on-body anchors, and energy-related and other technological constraints (e.g., pulsebased modulation) at the nanodevice level. Accounting for these constraints, the framework can generate raw data to streamline into different flow-guided localization solutions for generating standardized performance benchmarks.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-27
DOI
https://doi.org/10.5281/zenodo.15144203
Primary Topic
Molecular Communication and Nanonetworks
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward Standardized Performance Evaluation of Flow-Guided Nanoscale Localization

Zenodo (CERN European Organization for Nuclear Research)
Molecular Communication and Nanonetworks
article

Toward Standardized Performance Evaluation of Flow-Guided Nanoscale Localization

article en

Abstract

Nanoscale devices with Terahertz (THz) communication capabilities are envisioned to be deployed within human bloodstreams. Such devices will enable fine-grained sensing-based applications for detecting early indications (i.e., biomarkers) of various health conditions, as well as actuation-based ones such as targeted drug delivery. Associating the locations of such events with the events themselves would provide an additional utility for precision diagnostics and treatment. This vision yielded a new class of in-body localization coined under the term “flow-guided nanoscale localization”. Such localization can be piggybacked on THz communication for detecting body regions in which biological events were localized with the traveling time reported by nanodevices flowing with the bloodstream. From decades of research on objective benchmarking of “traditional” indoor localization and its eventual standardization (e.g., ISO/IEC18305:2016), we know that in early stages, the reported performance results were often incomplete (e.g., targeting a subset of relevant performance metrics). Reported results in the literature carried out benchmarking experiments in different evaluation environments and scenarios and utilized inconsistent performance indicators. To avoid such a “lock-in” in flowguided localization, we propose a workflow for standardized performance evaluation of such approaches. The workflow is implemented in the form of an open-source simulation framework that is able to jointly account for the mobility of the nanodevices, in-body THz communication with on-body anchors, and energy-related and other technological constraints (e.g., pulsebased modulation) at the nanodevice level. Accounting for these constraints, the framework can generate raw data to streamline into different flow-guided localization solutions for generating standardized performance benchmarks.

Zenodo (CERN European Organization for Nuclear Research)
Institució Catalana de Recerca i Estudis Avançats (ES), University of Antwerp (BE), i2CAT (ES), Technische Universität Berlin (DE), Universitat Politècnica de Catalunya (ES)
Openalex Percentile: Top 67%
Molecular Communication and Nanonetworks
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Toward Standardized Performance Evaluation of Flow-Guided Nanoscale Localization · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS