A Prospective Study on Errors in Pre-Analytical Phase in Central Laboratory: Biochemistry Unit

Background: Pre-analytical errors are a significant source of inaccuracies in clinical biochemistry laboratories, contributing to approximately 60-70% of total laboratory errors. These errors arise during the pre-examination phase, which spans from test ordering to sample analysis. Given the potential impact on diagnostic outcomes, understanding and mitigating these errors is critical to improving laboratory quality.  Objectives: The study aims to enumerate and analyze the frequency of pre-analytical errors in a Clinical Biochemistry laboratory, with a particular focus on assessing the effect of hemolysis on blood glucose levels.  Materials and Methods: Data were collected across various hospital departments, and the occurrence of pre-analytical errors was assessed. The analysis focused on the impact of hemolysis on test results, particularly blood glucose measurements.  Results: The findings reveal significant variation in the frequency of pre-analytical errors across different clinical departments. The Inpatient Department accounted for the highest proportion of errors (50.36%), followed by the Critical Care Medicine department at 43.13%. In contrast, lower rates of errors were observed in the Emergency Department (3.61%) and Outpatient Department (2.89%). Hemolysis was identified as the most prevalent error type, followed by issues such as inadequate sample volume, improper tube selection, labeling errors, and clot formation in serum samples. These findings underscore that pre-analytical errors are particularly common in inpatient and critical care settings, suggesting the need for targeted interventions in these areas.  Conclusion: The study highlights the significant role of pre-analytical factors in shaping laboratory test outcomes. Hemolysis, inadequate sample volume, and other procedural errors were found to be the most frequent contributors to inaccurate results. The research emphasizes the importance of adhering to standardized protocols and implementing quality control measures to reduce errors, enhance the accuracy of laboratory testing, and ultimately improve patient care.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-10
DOI
https://doi.org/10.5281/zenodo.14836649
Primary Topic
Functional Brain Connectivity Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Prospective Study on Errors in Pre-Analytical Phase in Central Laboratory: Biochemistry Unit

Zenodo (CERN European Organization for Nuclear Research)
Functional Brain Connectivity Studies
article

A Prospective Study on Errors in Pre-Analytical Phase in Central Laboratory: Biochemistry Unit

article en

Abstract

Background: Pre-analytical errors are a significant source of inaccuracies in clinical biochemistry laboratories, contributing to approximately 60-70% of total laboratory errors. These errors arise during the pre-examination phase, which spans from test ordering to sample analysis. Given the potential impact on diagnostic outcomes, understanding and mitigating these errors is critical to improving laboratory quality.  Objectives: The study aims to enumerate and analyze the frequency of pre-analytical errors in a Clinical Biochemistry laboratory, with a particular focus on assessing the effect of hemolysis on blood glucose levels.  Materials and Methods: Data were collected across various hospital departments, and the occurrence of pre-analytical errors was assessed. The analysis focused on the impact of hemolysis on test results, particularly blood glucose measurements.  Results: The findings reveal significant variation in the frequency of pre-analytical errors across different clinical departments. The Inpatient Department accounted for the highest proportion of errors (50.36%), followed by the Critical Care Medicine department at 43.13%. In contrast, lower rates of errors were observed in the Emergency Department (3.61%) and Outpatient Department (2.89%). Hemolysis was identified as the most prevalent error type, followed by issues such as inadequate sample volume, improper tube selection, labeling errors, and clot formation in serum samples. These findings underscore that pre-analytical errors are particularly common in inpatient and critical care settings, suggesting the need for targeted interventions in these areas.  Conclusion: The study highlights the significant role of pre-analytical factors in shaping laboratory test outcomes. Hemolysis, inadequate sample volume, and other procedural errors were found to be the most frequent contributors to inaccurate results. The research emphasizes the importance of adhering to standardized protocols and implementing quality control measures to reduce errors, enhance the accuracy of laboratory testing, and ultimately improve patient care.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 51%
Functional Brain Connectivity Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Prospective Study on Errors in Pre-Analytical Phase in Central Laboratory: Biochemistry Unit · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS