ANALISIS UMUR PAKAI OLI PADA FAN PLTU TE 3x10 MW

One of the boiler auxiliaries for the running of the production process is the fan. The fan acts as a primary and secondary air supply and as a vacuum cleaner for the remaining ash when the boiler burns and is discharged into the atmosphere. In this fan often occurs over heat (over heat) one of the causes is the decline in oil quality. Lack of attention to the lubrication system if allowed to continue will experience over heat in the fan which will cause damage to the fan, especially the bearing due to the decrease in oil viscosity caused by operating hours and temperatures that affect the oil in the fan. The data obtained will be processed and analyzed with a Quantitative to see the effect of running hours and temperature on the kinematic viscosity of oil samples. From this study with a test of 40 ° C obtained results at 0 hours (92.88 cSt), 1923 hours (57.94 cSt), 2012 hours (53.26 cSt), 2195 hours (46.82 cSt), 2202 hours (44.75 cSt), 2207 hours (43.26 cSt). From the results of this study, running hours greatly affect the kinematic viscosity value and temperature treatment of oil affects the kinematic viscosity along with the increase in running hours.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-28
DOI
https://doi.org/10.5281/zenodo.14942716
Primary Topic
Fluid dynamics and aerodynamics studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALISIS UMUR PAKAI OLI PADA FAN PLTU TE 3x10 MW

Zenodo (CERN European Organization for Nuclear Research)
Fluid dynamics and aerodynamics studies
article

ANALISIS UMUR PAKAI OLI PADA FAN PLTU TE 3x10 MW

article en

Abstract

One of the boiler auxiliaries for the running of the production process is the fan. The fan acts as a primary and secondary air supply and as a vacuum cleaner for the remaining ash when the boiler burns and is discharged into the atmosphere. In this fan often occurs over heat (over heat) one of the causes is the decline in oil quality. Lack of attention to the lubrication system if allowed to continue will experience over heat in the fan which will cause damage to the fan, especially the bearing due to the decrease in oil viscosity caused by operating hours and temperatures that affect the oil in the fan. The data obtained will be processed and analyzed with a Quantitative to see the effect of running hours and temperature on the kinematic viscosity of oil samples. From this study with a test of 40 ° C obtained results at 0 hours (92.88 cSt), 1923 hours (57.94 cSt), 2012 hours (53.26 cSt), 2195 hours (46.82 cSt), 2202 hours (44.75 cSt), 2207 hours (43.26 cSt). From the results of this study, running hours greatly affect the kinematic viscosity value and temperature treatment of oil affects the kinematic viscosity along with the increase in running hours.

Zenodo (CERN European Organization for Nuclear Research)
Sriwijaya University (ID), Politeknik Negeri Sriwijaya (ID)
Industry, innovation and infrastructure
Openalex Percentile: Top 52%
Fluid dynamics and aerodynamics studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ANALISIS UMUR PAKAI OLI PADA FAN PLTU TE 3x10 MW · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS