High-Performance Liquid Chromatographic Technique For Evaluating Solifenacin Succinate Incorporated Into Overactive Bladder Syndrome Treatment

The detection of solifenacin succinate was successfully achieved by developing and validating a new, isocratic, rapid, specific, sensitive reversed phase high-performance liquid chromatographic (RP-HPLC) method. A stationary phase of the HiQ Sil C18 (250 x 4.6 mm) column with a temperature of 25oC was used to quantify solifenacin succinate. The mobile phase ACN: Methanol (85.5:14.5 v/v) at a flow rate of 0.7 mL/min was selected to produce the chromatographic separation of solifenacin succinate, and a photodiode array (PDA) detector operating at 221 nm was used for detection. The linear regression analysis results for plotting the calibration curve showed a good linear relation with r2 = 0.999 with the concentration range of 10–60 µg mL−1. 6.15μg mL−1 was the limit of quantitation (LOQ) and 2.02 μg mL−1 was the limit of detection (LOD). The developed technique was determined to comply with ICH guidelines for parameters like specificity, linearity, precision, accuracy, limit of detection, and limit of quantification.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-11
DOI
https://doi.org/10.5281/zenodo.14397385
Primary Topic
Digital Media Forensic Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Performance Liquid Chromatographic Technique For Evaluating Solifenacin Succinate Incorporated Into Overactive Bladder Syndrome Treatment

Zenodo (CERN European Organization for Nuclear Research)
Digital Media Forensic Detection
article

High-Performance Liquid Chromatographic Technique For Evaluating Solifenacin Succinate Incorporated Into Overactive Bladder Syndrome Treatment

article en

Abstract

The detection of solifenacin succinate was successfully achieved by developing and validating a new, isocratic, rapid, specific, sensitive reversed phase high-performance liquid chromatographic (RP-HPLC) method. A stationary phase of the HiQ Sil C18 (250 x 4.6 mm) column with a temperature of 25oC was used to quantify solifenacin succinate. The mobile phase ACN: Methanol (85.5:14.5 v/v) at a flow rate of 0.7 mL/min was selected to produce the chromatographic separation of solifenacin succinate, and a photodiode array (PDA) detector operating at 221 nm was used for detection. The linear regression analysis results for plotting the calibration curve showed a good linear relation with r2 = 0.999 with the concentration range of 10–60 µg mL−1. 6.15μg mL−1 was the limit of quantitation (LOQ) and 2.02 μg mL−1 was the limit of detection (LOD). The developed technique was determined to comply with ICH guidelines for parameters like specificity, linearity, precision, accuracy, limit of detection, and limit of quantification.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 63%
Digital Media Forensic Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.