Analysis of Cooling Load Calculation 2nd Floor Building F, Engineering Faculty Widyatama University

The air conditioning system is the process of regulating air, which includes air temperature, humidity, and air quality. Air conditioning in the classroom is an important factor to support the teaching and learning process. On the second floor of Building F, there are 3 classrooms. Each classroom has 2 air conditioners of the split type. When room has a full number of students, the air temperature in the room is very uncomfortable due to the heat. This research purposes are to calculate the maximum cooling load for these three classrooms, and to provide recommendations to the relevant parties regarding the required cooling capacity. The research method used is the analysis of the cooling load calculations for the air conditioning system. The research results are the total heat load for classroom F200 is 6.081 PK, classroom F201 is 5.956 PK, and classroom F202 is 6.236 PK, while the existing cooling capacity for each classroom is 3 PK. Therefore, the cooling capacity in the three classrooms on the second floor of Building F does not meet the maximum cooling load requirements. The recommendation from this research is that an additional air conditioning capacity of 3 PK is needed for each room.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-02-21
DOI
https://doi.org/10.5281/zenodo.14899175
Primary Topic
IoT-based Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Cooling Load Calculation 2nd Floor Building F, Engineering Faculty Widyatama University

Zenodo (CERN European Organization for Nuclear Research)
IoT-based Control Systems
article

Analysis of Cooling Load Calculation 2nd Floor Building F, Engineering Faculty Widyatama University

article en

Abstract

The air conditioning system is the process of regulating air, which includes air temperature, humidity, and air quality. Air conditioning in the classroom is an important factor to support the teaching and learning process. On the second floor of Building F, there are 3 classrooms. Each classroom has 2 air conditioners of the split type. When room has a full number of students, the air temperature in the room is very uncomfortable due to the heat. This research purposes are to calculate the maximum cooling load for these three classrooms, and to provide recommendations to the relevant parties regarding the required cooling capacity. The research method used is the analysis of the cooling load calculations for the air conditioning system. The research results are the total heat load for classroom F200 is 6.081 PK, classroom F201 is 5.956 PK, and classroom F202 is 6.236 PK, while the existing cooling capacity for each classroom is 3 PK. Therefore, the cooling capacity in the three classrooms on the second floor of Building F does not meet the maximum cooling load requirements. The recommendation from this research is that an additional air conditioning capacity of 3 PK is needed for each room.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 50%
IoT-based Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Cooling Load Calculation 2nd Floor Building F, Engineering Faculty Widyatama University · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS