Analysis of Lightning Arrester Installation Location on Transformer 1 Bungaran Substation

Lightning arrester is a device used in substations to protect electrical equipment from voltage increases caused by solar circuits or lightning. The purpose of the study is to calculate the lighting arrester spark voltage and voltage rise on the transformer, and analyse the lightning arrester distance to the power transformer and protection factor. Surge voltages, due to disturbances such as lightning strikes, can be very high without lightning arresters, namely 305,065 kV at t = 10 μsec. With an arrester, the voltage is reduced to 262,726 kV from t = 9,05 μsec to 220,387 kV at t = 10 μsec, indicating effective protection. Without lightning arresters, the clamping voltage on the transformer can reach 340,442 kV at t = 12 μsec, exceeding the BIL (325 kV) and risking damage. With an arrester, the pinch voltage is dampened from 306,777 kV at t = 11,05 μsec to 273,169 kV at t = 12 μsec, keeping it below the BIL. The optimal distance of lightning arrester placement at Bungaran Substation is 6,6077 m, while the installed distance is 7 m. This distance complies with PT PLN's standard of up to 34 m for double-circuit transmission, ensuring effective protection. The lightning arrester provides good protection for the 30 MVA Power Transformer with a protection level of 288,998 kV and a protection factor of 11,0774%. This keeps the voltage below BIL (325 kV), effectively reducing the risk of damage from voltage surges.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-08-15
DOI
https://doi.org/10.5281/zenodo.13335109
Primary Topic
Ruminant Nutrition and Digestive Physiology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Lightning Arrester Installation Location on Transformer 1 Bungaran Substation

Zenodo (CERN European Organization for Nuclear Research)
Ruminant Nutrition and Digestive Physiology
article

Analysis of Lightning Arrester Installation Location on Transformer 1 Bungaran Substation

article en

Abstract

Lightning arrester is a device used in substations to protect electrical equipment from voltage increases caused by solar circuits or lightning. The purpose of the study is to calculate the lighting arrester spark voltage and voltage rise on the transformer, and analyse the lightning arrester distance to the power transformer and protection factor. Surge voltages, due to disturbances such as lightning strikes, can be very high without lightning arresters, namely 305,065 kV at t = 10 μsec. With an arrester, the voltage is reduced to 262,726 kV from t = 9,05 μsec to 220,387 kV at t = 10 μsec, indicating effective protection. Without lightning arresters, the clamping voltage on the transformer can reach 340,442 kV at t = 12 μsec, exceeding the BIL (325 kV) and risking damage. With an arrester, the pinch voltage is dampened from 306,777 kV at t = 11,05 μsec to 273,169 kV at t = 12 μsec, keeping it below the BIL. The optimal distance of lightning arrester placement at Bungaran Substation is 6,6077 m, while the installed distance is 7 m. This distance complies with PT PLN's standard of up to 34 m for double-circuit transmission, ensuring effective protection. The lightning arrester provides good protection for the 30 MVA Power Transformer with a protection level of 288,998 kV and a protection factor of 11,0774%. This keeps the voltage below BIL (325 kV), effectively reducing the risk of damage from voltage surges.

Zenodo (CERN European Organization for Nuclear Research)
Universitas Palembang (ID)
Affordable and clean energy
Openalex Percentile: Top 49%
Ruminant Nutrition and Digestive Physiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.