Exergy-Based Sustainability Analysis of a Two- Stage Vapour Compression Refrigeration System Using Hybrid Nano-Refrigerant

Refrigeration technology is designed to provide cooling based on the principle of rejection of heat to the surrounding at higher temperature and absorption of heat at low temperature. The performance of a vapour compression refrigeration system can be enhanced by improving the performance parameters of the system. In this study, comparative analysis of hybrid Nano refrigerant and R134a only as refrigerants in two stage vapour compression refrigeration system has been done on the basis of energetic and exergy-based sustainability performance. The performance parameters of the system such as the coefficient of performance (COP), exergy destruction and sustainability index were investigated experimentally at different temperatures of the evaporator and condenser, and also at different volume concentrations of the Nano-particles using TPS-3950, TPS-3951 and TPS-3952 equipment. It was later validated using the Engineering equation solver software. The results obtained show that at evaporator temperature of 243°K and condenser temperature of 321°K, the COP of the system increased by 7.8%, exergy destruction decreased by 16.9% and sustainability index decreased by 1.6% using the hybrid Nano refrigerant when compared with pure refrigerant. It was also observed that the coefficient of performance is higher when using hybrid Nano-refrigerant when compared with using R134a only. The sustainability index and Exergy destruction of the system is smaller when using hybrid Nano-refrigerant when compared with using R134a only. It was observed that the coefficient of performance and sustainability index increases with increase in evaporator temperature. While the exergy destruction of the system decreases with increase in evaporator temperature. Also, the COP decreases with increase in condenser temperature. While the exergy destruction and sustainability index of the system increases with increase in condenser temperature. The COP increases with increase in volumetric concentration of the hybrid Nano particles. Whereas, the sustainability index and exergy destruction of the system decreases with increase in volumetric concentration of the hybrid Nano particles. In conclusion, the system performs better using hybrid Nano-refrigerant but it is less sustainable.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-05
DOI
https://doi.org/10.5281/zenodo.14282270
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exergy-Based Sustainability Analysis of a Two- Stage Vapour Compression Refrigeration System Using Hybrid Nano-Refrigerant

Zenodo (CERN European Organization for Nuclear Research)
Refrigeration and Air Conditioning Technologies
article

Exergy-Based Sustainability Analysis of a Two- Stage Vapour Compression Refrigeration System Using Hybrid Nano-Refrigerant

article en

Abstract

Refrigeration technology is designed to provide cooling based on the principle of rejection of heat to the surrounding at higher temperature and absorption of heat at low temperature. The performance of a vapour compression refrigeration system can be enhanced by improving the performance parameters of the system. In this study, comparative analysis of hybrid Nano refrigerant and R134a only as refrigerants in two stage vapour compression refrigeration system has been done on the basis of energetic and exergy-based sustainability performance. The performance parameters of the system such as the coefficient of performance (COP), exergy destruction and sustainability index were investigated experimentally at different temperatures of the evaporator and condenser, and also at different volume concentrations of the Nano-particles using TPS-3950, TPS-3951 and TPS-3952 equipment. It was later validated using the Engineering equation solver software. The results obtained show that at evaporator temperature of 243°K and condenser temperature of 321°K, the COP of the system increased by 7.8%, exergy destruction decreased by 16.9% and sustainability index decreased by 1.6% using the hybrid Nano refrigerant when compared with pure refrigerant. It was also observed that the coefficient of performance is higher when using hybrid Nano-refrigerant when compared with using R134a only. The sustainability index and Exergy destruction of the system is smaller when using hybrid Nano-refrigerant when compared with using R134a only. It was observed that the coefficient of performance and sustainability index increases with increase in evaporator temperature. While the exergy destruction of the system decreases with increase in evaporator temperature. Also, the COP decreases with increase in condenser temperature. While the exergy destruction and sustainability index of the system increases with increase in condenser temperature. The COP increases with increase in volumetric concentration of the hybrid Nano particles. Whereas, the sustainability index and exergy destruction of the system decreases with increase in volumetric concentration of the hybrid Nano particles. In conclusion, the system performs better using hybrid Nano-refrigerant but it is less sustainable.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 65%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.