Calculation of Stable Controller Values for Single Area Isolated Power System using Boundary Locus Method

The power system's operating point fluctuates constantly due to its extremely nonlinear nature. As a result, both actual and reactive power are impacted by the extremely low system performance. Real power shifts mostly impact the Changes in voltage magnitude are the primary determinant of changes in reactive power and system frequency. Reactive and real capabilities can therefore be managed independently. The Automatic Voltage Regulator (AVR) regulates the voltage magnitude and, therefore, the reactive power, whereas the Load Frequency Control (LFC) controls the actual power. The regulating of generator power output is known as load frequency control, or LFC, in an interconnected system. Generally speaking, fixed gain controllers are made for nominal operating settings and don't offer the optimal control performance under a variety of operating circumstances. Therefore, it is preferable to monitor operating circumstances and compute the control using updated parameters in order to maintain system performance close to optimal. Using the "Boundary Locus Method," a novel approach to identifying stabilising PID controllers for the LFC control system loop has been put forth in this study.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-05
DOI
https://doi.org/10.5281/zenodo.14280020
Primary Topic
Atmospheric Ozone and Climate
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculation of Stable Controller Values for Single Area Isolated Power System using Boundary Locus Method

Zenodo (CERN European Organization for Nuclear Research)
Atmospheric Ozone and Climate
article

Calculation of Stable Controller Values for Single Area Isolated Power System using Boundary Locus Method

article en

Abstract

The power system's operating point fluctuates constantly due to its extremely nonlinear nature. As a result, both actual and reactive power are impacted by the extremely low system performance. Real power shifts mostly impact the Changes in voltage magnitude are the primary determinant of changes in reactive power and system frequency. Reactive and real capabilities can therefore be managed independently. The Automatic Voltage Regulator (AVR) regulates the voltage magnitude and, therefore, the reactive power, whereas the Load Frequency Control (LFC) controls the actual power. The regulating of generator power output is known as load frequency control, or LFC, in an interconnected system. Generally speaking, fixed gain controllers are made for nominal operating settings and don't offer the optimal control performance under a variety of operating circumstances. Therefore, it is preferable to monitor operating circumstances and compute the control using updated parameters in order to maintain system performance close to optimal. Using the "Boundary Locus Method," a novel approach to identifying stabilising PID controllers for the LFC control system loop has been put forth in this study.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 64%
Atmospheric Ozone and Climate
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Calculation of Stable Controller Values for Single Area Isolated Power System using Boundary Locus Method · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS