ANALYTICAL METHOD DEVELOPMENT OF DEFLAZACORT BY USING UV-SPECTROSCOPY

Deflazacort, a corticosteroid employed in the treatment of Duchenne muscular dystrophy, lacked a UV method utilizing minimal organic solvent according to our literature review. Therefore, a novel UV method development consuming very little organic solvent was undertaken in this study. Several key validation parameters, including accuracy, linearity, and precision, were evaluated in accordance with ICH guidelines. UV spectroscopic determination was performed at the absorption maximum of 245 nm, employing a mixture of methanol and water as the solvent system. The obtained results underwent statistical validation. The developed method demonstrated simplicity, rapidity, precision, and accuracy, rendering it suitable for UV analysis of deflazacort. In this UV method development, linearity was established within the range of 0.5-8 μg/mL, with a correlation coefficient (r²) of 0.9998.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-26
DOI
https://doi.org/10.5281/zenodo.14557929
Primary Topic
Herpesvirus Infections and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYTICAL METHOD DEVELOPMENT OF DEFLAZACORT BY USING UV-SPECTROSCOPY

Zenodo (CERN European Organization for Nuclear Research)
Herpesvirus Infections and Treatments
article

ANALYTICAL METHOD DEVELOPMENT OF DEFLAZACORT BY USING UV-SPECTROSCOPY

article en

Abstract

Deflazacort, a corticosteroid employed in the treatment of Duchenne muscular dystrophy, lacked a UV method utilizing minimal organic solvent according to our literature review. Therefore, a novel UV method development consuming very little organic solvent was undertaken in this study. Several key validation parameters, including accuracy, linearity, and precision, were evaluated in accordance with ICH guidelines. UV spectroscopic determination was performed at the absorption maximum of 245 nm, employing a mixture of methanol and water as the solvent system. The obtained results underwent statistical validation. The developed method demonstrated simplicity, rapidity, precision, and accuracy, rendering it suitable for UV analysis of deflazacort. In this UV method development, linearity was established within the range of 0.5-8 μg/mL, with a correlation coefficient (r²) of 0.9998.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 52%
Herpesvirus Infections and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.