The impact of Scattering Correction Techniques on The performance of Gamma Camera

In nuclear medicine, scattering correction plays a crucial role in improving the accuracy and reliability of diagnostic imaging techniques such as nuclear medicines such as single -photon emission computed tomography (SPECT) . The main aim of measuring scattering correction in gamma camera is to improve the accuracy and reliability of diagnostic images. Correction was made for attenuation by transmission measurements. Three different scatter correction methods were used; the Triple Energy Window method (TEW), the Double Energy Window method (DEW) and the Lower Energy Window method (LEW). The scatter correction gave an underestimation ranging between 20% and 0.5 % (for 99mTc and all organs) depending on the correction methods used. For 123I, these values ranged between an overestimation of 14% and 1.2 %. For higher background activities, the deviation from the true activity values became higher, but reasonably accurate. The most consequent results when considering all organs and organ-to-background activities was found when applying the LEW scatter correction method combined with the Bujis background correction method. 123I is the most accurate results of attenuation and scatter correction was obtained for large organs when applying the TEW method.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-03-25
DOI
https://doi.org/10.5281/zenodo.15085839
Primary Topic
Odor and Emission Control Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of Scattering Correction Techniques on The performance of Gamma Camera

Zenodo (CERN European Organization for Nuclear Research)
Odor and Emission Control Technologies
article

The impact of Scattering Correction Techniques on The performance of Gamma Camera

article en

Abstract

In nuclear medicine, scattering correction plays a crucial role in improving the accuracy and reliability of diagnostic imaging techniques such as nuclear medicines such as single -photon emission computed tomography (SPECT) . The main aim of measuring scattering correction in gamma camera is to improve the accuracy and reliability of diagnostic images. Correction was made for attenuation by transmission measurements. Three different scatter correction methods were used; the Triple Energy Window method (TEW), the Double Energy Window method (DEW) and the Lower Energy Window method (LEW). The scatter correction gave an underestimation ranging between 20% and 0.5 % (for 99mTc and all organs) depending on the correction methods used. For 123I, these values ranged between an overestimation of 14% and 1.2 %. For higher background activities, the deviation from the true activity values became higher, but reasonably accurate. The most consequent results when considering all organs and organ-to-background activities was found when applying the LEW scatter correction method combined with the Bujis background correction method. 123I is the most accurate results of attenuation and scatter correction was obtained for large organs when applying the TEW method.

Zenodo (CERN European Organization for Nuclear Research)
Alytus College (LT), Kaya University (KR), Libyan International Medical University (LY)
Affordable and clean energy
Openalex Percentile: Top 63%
Odor and Emission Control Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The impact of Scattering Correction Techniques on The performance of Gamma Camera · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS