DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR SIMULTANEOUS ESTIMATION OF MONTELUKAST AND DOXYFYLLINE BY RP-HPLC

The development and validation of a reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of Montelukast and Doxofylline in pharmaceutical formulations were carried out. The method was optimized using a Waters HPLC system equipped with an auto-sampler and PDA detector (996 model). A Phenomenex Luna C18 column (4.6×250mm, 5µm) was employed for the separation of both drugs. The mobile phase consisted of acetonitrile and phosphate buffer (pH 4.6) in a 45:55 (v/v) ratio, with a flow rate of 1.0 ml/min. The wavelength for detection was set at 245 nm, and the injection volume was 10 µL. The column temperature was maintained at 35°C, and the total run time was 7 minutes. The method was validated as per ICH guidelines, and the results demonstrated excellent linearity, precision, accuracy, and robustness. The proposed method offers a simple, rapid, and reliable approach for the simultaneous estimation of Montelukast and Doxofylline in tablet dosage forms, and can be effectively used for quality control in pharmaceutical industries. Keywords: Montelukast and Doxofylline, RP-HPLC, Simultaneous Estimation, Pharmaceutical Dosage Forms, Waters HPLC.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-12-30
DOI
https://doi.org/10.5281/zenodo.14577865
Primary Topic
Enzyme Production and Characterization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR SIMULTANEOUS ESTIMATION OF MONTELUKAST AND DOXYFYLLINE BY RP-HPLC

Zenodo (CERN European Organization for Nuclear Research)
Enzyme Production and Characterization
article

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR SIMULTANEOUS ESTIMATION OF MONTELUKAST AND DOXYFYLLINE BY RP-HPLC

article en

Abstract

The development and validation of a reverse-phase high-performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of Montelukast and Doxofylline in pharmaceutical formulations were carried out. The method was optimized using a Waters HPLC system equipped with an auto-sampler and PDA detector (996 model). A Phenomenex Luna C18 column (4.6×250mm, 5µm) was employed for the separation of both drugs. The mobile phase consisted of acetonitrile and phosphate buffer (pH 4.6) in a 45:55 (v/v) ratio, with a flow rate of 1.0 ml/min. The wavelength for detection was set at 245 nm, and the injection volume was 10 µL. The column temperature was maintained at 35°C, and the total run time was 7 minutes. The method was validated as per ICH guidelines, and the results demonstrated excellent linearity, precision, accuracy, and robustness. The proposed method offers a simple, rapid, and reliable approach for the simultaneous estimation of Montelukast and Doxofylline in tablet dosage forms, and can be effectively used for quality control in pharmaceutical industries. Keywords: Montelukast and Doxofylline, RP-HPLC, Simultaneous Estimation, Pharmaceutical Dosage Forms, Waters HPLC.

Zenodo (CERN European Organization for Nuclear Research)
Industry, innovation and infrastructure
Openalex Percentile: Top 55%
Enzyme Production and Characterization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.