Development & Validation Of RP-HPLC Method For Analytical Evaluation Of Ribociclib In Bulk Drug And Pharmaceutical Dosage Form

Purpose: A new Reverse Phase high-performance liquid chromatography (RP-HPLC) method was developed for the quantitative determination of ribociclib bulk and its tablet dosage form. Method: The chromatographic separation was achieved on Symmetry ODS C18 (4.6×150mm, 5µm). The mobile phase selected was Methanol: Phosphate Buffer pH-4.2 in the ratio of 35:65% v/v at a flow rate of 1ml/min with column temperature maintained at 40°C and 10µl injection volume. The detection was carried out at 276 nm. Results: The retention time of Ribociclib was found to be 3.02 min. The developed HPLC method was validated as per ICH (Q2R1) guidelines. The HPLC method was linear over the range of 10-50µg/ml with a regression coefficient of 0.999.The %recovery for accuracy was found to be 100.1-100.4.The % purity for assay was found to be 99.57%.Conclusion: The developed HPLC method was a simple, sensitive, precise, accurate, robust and economical therefore, it can be applied for routine quality control analysis of Ribociclib in its tablet dosage form.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2024-10-12
DOI
https://doi.org/10.5281/zenodo.13923935
Primary Topic
Cancer, Stress, Anesthesia, and Immune Response
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development & Validation Of RP-HPLC Method For Analytical Evaluation Of Ribociclib In Bulk Drug And Pharmaceutical Dosage Form

Zenodo (CERN European Organization for Nuclear Research)
Cancer, Stress, Anesthesia, and Immune Response
article

Development & Validation Of RP-HPLC Method For Analytical Evaluation Of Ribociclib In Bulk Drug And Pharmaceutical Dosage Form

article en

Abstract

Purpose: A new Reverse Phase high-performance liquid chromatography (RP-HPLC) method was developed for the quantitative determination of ribociclib bulk and its tablet dosage form. Method: The chromatographic separation was achieved on Symmetry ODS C18 (4.6×150mm, 5µm). The mobile phase selected was Methanol: Phosphate Buffer pH-4.2 in the ratio of 35:65% v/v at a flow rate of 1ml/min with column temperature maintained at 40°C and 10µl injection volume. The detection was carried out at 276 nm. Results: The retention time of Ribociclib was found to be 3.02 min. The developed HPLC method was validated as per ICH (Q2R1) guidelines. The HPLC method was linear over the range of 10-50µg/ml with a regression coefficient of 0.999.The %recovery for accuracy was found to be 100.1-100.4.The % purity for assay was found to be 99.57%.Conclusion: The developed HPLC method was a simple, sensitive, precise, accurate, robust and economical therefore, it can be applied for routine quality control analysis of Ribociclib in its tablet dosage form.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 53%
Cancer, Stress, Anesthesia, and Immune Response
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development & Validation Of RP-HPLC Method For Analytical Evaluation Of Ribociclib In Bulk Drug And Pharmaceutical Dosage Form · Zenodo (CERN European Organization for Nuclear Research) (2024) | TGRS Research Map | TGRS