Photon-Counting CT Iodine Maps for Diagnosing Chronic Pulmonary Thromboembolism : A Pilot Study

OBJECTIVES The aim of this study was to evaluate the feasibility and efficacy of chronic pulmonary thromboembolism assessment using photon-counting detector computed tomography (PCD-CT) iodine maps of the lung parenchyma. MATERIALS AND METHODS This institutional review board-approved retrospective study included 83 subjects (49.4% male, aged 62.4 ± 13.4 years; 50.6% female, aged 59.9 ± 17.1 years) who underwent clinically indicated PCD-CT scan to rule out chronic thromboembolic pulmonary hypertension (CTEPH). Two blinded readers used iodine maps and corresponding sharp-kernel CT reconstructions in the lung window to evaluate perfusion defects and identify patients with chronic pulmonary thromboembolism (CTEPH, CTEPH overlap with other causes of pulmonary hypertension [PH], chronic thromboembolic disease [CTED]). No other clinical or imaging information was given. Discordance was resolved in a subsequent consensus read. The clinical diagnosis was reviewed in an interdisciplinary clinical setting. The accuracy, sensitivity, and specificity of radiologic evaluation and clinical diagnosis were calculated. RESULTS Of the 83 subjects included, 32 were diagnosed with CTEPH, CTEPH overlap, or CTED, 35 were diagnosed with PH caused by other pathologic mechanisms, 10 had no PH, and 6 had suffered previous acute pulmonary embolism, which resolved. The interreader agreement was good (Cohen κ = 0.74). The consensus reached high accuracy (0.88), sensitivity (0.94), and specificity (0.84), as well as good agreement with interdisciplinary clinical diagnosis (Cohen κ = 0.75). No cases with confirmed CTEPH as the primary cause of PH or CTED were missed. Patients with pulmonary arterial hypertension were most frequently rated false-positive. The mean effective dose (±standard deviation) was 1.3 (±0.76) mSv. CONCLUSIONS Accurate, sensitive, and specific diagnosis of pulmonary chronic thromboembolism at low radiation dose is possible using iodine maps reconstructed from PCD-CT scans.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2025-05-01
DOI
https://doi.org/10.5167/uzh-266409
Citations
3
Primary Topic
Insect-Plant Interactions and Control
Type
article
Field-Weighted Citation Impact
5.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photon-Counting CT Iodine Maps for Diagnosing Chronic Pulmonary Thromboembolism : A Pilot Study

3 citations
Zurich Open Repository and Archive (University of Zurich)
Insect-Plant Interactions and Control
5.02
article

Photon-Counting CT Iodine Maps for Diagnosing Chronic Pulmonary Thromboembolism : A Pilot Study

article en
3 citations

Abstract

OBJECTIVES The aim of this study was to evaluate the feasibility and efficacy of chronic pulmonary thromboembolism assessment using photon-counting detector computed tomography (PCD-CT) iodine maps of the lung parenchyma. MATERIALS AND METHODS This institutional review board-approved retrospective study included 83 subjects (49.4% male, aged 62.4 ± 13.4 years; 50.6% female, aged 59.9 ± 17.1 years) who underwent clinically indicated PCD-CT scan to rule out chronic thromboembolic pulmonary hypertension (CTEPH). Two blinded readers used iodine maps and corresponding sharp-kernel CT reconstructions in the lung window to evaluate perfusion defects and identify patients with chronic pulmonary thromboembolism (CTEPH, CTEPH overlap with other causes of pulmonary hypertension [PH], chronic thromboembolic disease [CTED]). No other clinical or imaging information was given. Discordance was resolved in a subsequent consensus read. The clinical diagnosis was reviewed in an interdisciplinary clinical setting. The accuracy, sensitivity, and specificity of radiologic evaluation and clinical diagnosis were calculated. RESULTS Of the 83 subjects included, 32 were diagnosed with CTEPH, CTEPH overlap, or CTED, 35 were diagnosed with PH caused by other pathologic mechanisms, 10 had no PH, and 6 had suffered previous acute pulmonary embolism, which resolved. The interreader agreement was good (Cohen κ = 0.74). The consensus reached high accuracy (0.88), sensitivity (0.94), and specificity (0.84), as well as good agreement with interdisciplinary clinical diagnosis (Cohen κ = 0.75). No cases with confirmed CTEPH as the primary cause of PH or CTED were missed. Patients with pulmonary arterial hypertension were most frequently rated false-positive. The mean effective dose (±standard deviation) was 1.3 (±0.76) mSv. CONCLUSIONS Accurate, sensitive, and specific diagnosis of pulmonary chronic thromboembolism at low radiation dose is possible using iodine maps reconstructed from PCD-CT scans.

Zurich Open Repository and Archive (University of Zurich)
Good health and well-being
Openalex Percentile: Top 5%
Insect-Plant Interactions and Control
5.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Photon-Counting CT Iodine Maps for Diagnosing Chronic Pulmonary Thromboembolism : A Pilot Study · Zurich Open Repository and Archive (University of Zurich) (2025) | TGRS Research Map | TGRS