χ (2)-induced artifact overwhelming the third-order signal in 2D Raman-THz spectroscopy of non-centrosymmetric materials.

Through comprehensive data analysis, we demonstrate that a χ(2)-induced artifact, arising from imperfect balancing in the conventional electro-optic sampling detection scheme, contributes significantly to the measured signal in 2D Raman-THz spectroscopy of non-centrosymmetric materials. The artifact is a product of two 1D responses, overwhelming the desired 2D response. We confirm that by analyzing the 2D Raman-THz response of an x-cut beta barium borate crystal. We furthermore show that this artifact can be effectively suppressed by implementing a special detection scheme. We successfully isolate the desired third-order 2D Raman-THz response, revealing a distinct cross-peak feature, whose frequency position suggests the coupling between two crystal phonons.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-10-07
DOI
https://doi.org/10.48620/36467
Primary Topic
Memory Processes and Influences
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

χ (2)-induced artifact overwhelming the third-order signal in 2D Raman-THz spectroscopy of non-centrosymmetric materials.

Open Access CRIS of the University of Bern
Memory Processes and Influences
article

χ (2)-induced artifact overwhelming the third-order signal in 2D Raman-THz spectroscopy of non-centrosymmetric materials.

article en

Abstract

Through comprehensive data analysis, we demonstrate that a χ(2)-induced artifact, arising from imperfect balancing in the conventional electro-optic sampling detection scheme, contributes significantly to the measured signal in 2D Raman-THz spectroscopy of non-centrosymmetric materials. The artifact is a product of two 1D responses, overwhelming the desired 2D response. We confirm that by analyzing the 2D Raman-THz response of an x-cut beta barium borate crystal. We furthermore show that this artifact can be effectively suppressed by implementing a special detection scheme. We successfully isolate the desired third-order 2D Raman-THz response, revealing a distinct cross-peak feature, whose frequency position suggests the coupling between two crystal phonons.

Open Access CRIS of the University of Bern
Laser Operations (United States) (US), Laser Research Institute (CN)
Openalex Percentile: Top 62%
Memory Processes and Influences
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.