Effect of reference objects on the accuracy of digital implant impressions in partially edentulous arches

PURPOSE This study assesses the impact of additional reference objects (RO) on the trueness and precision of distance and angle measurements between scan bodies in digital scans with four different intraoral scanners (IOS) in partially edentulous models. MATERIALS AND METHODS Maxilla models (Frasaco, Frasaco GmbH, Tettnang, Germany) with one (3-U) and two (4-U) missing posterior teeth were 3D printed and fitted with dental implants and scan bodies. Four intraoral scanners (Primescan (Dentsply Sirona, Charlotte, NC, USA) (PS), Trios 3 (3Shape) (T3), Trios 4 (3Shape) (T4), and CS3600 (Carestream Dentistry) (CS)) captured digital implant impressions with and without additional RO. Scans were aligned and assessed for distance and angulation measurements between scan bodies. Statistical analyses compared trueness and precision across model groups using the Student t-test and Welch's ANOVA. RESULTS CS consistently showed the highest distance values across IOS devices in both the 4-U and 3-U models (P < .05), both with and without RO. The distance values were not considerably affected by the presence of RO (P > .05), except for a few isolated cases in the PS and CS groups of 3-U models. When measuring angles, CS usually showed greater values than the other IOS devices, especially when RO was present both in the 4-U and 3-U variants (P < .05). CONCLUSION The influence of additional reference objects on accuracy varies with different scanner types, irrespective of edentulous area length.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2024-10-01
DOI
https://doi.org/10.5167/uzh-276684
Primary Topic
Ecology and Vegetation Dynamics Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of reference objects on the accuracy of digital implant impressions in partially edentulous arches

Zurich Open Repository and Archive (University of Zurich)
Ecology and Vegetation Dynamics Studies
article

Effect of reference objects on the accuracy of digital implant impressions in partially edentulous arches

article en

Abstract

PURPOSE This study assesses the impact of additional reference objects (RO) on the trueness and precision of distance and angle measurements between scan bodies in digital scans with four different intraoral scanners (IOS) in partially edentulous models. MATERIALS AND METHODS Maxilla models (Frasaco, Frasaco GmbH, Tettnang, Germany) with one (3-U) and two (4-U) missing posterior teeth were 3D printed and fitted with dental implants and scan bodies. Four intraoral scanners (Primescan (Dentsply Sirona, Charlotte, NC, USA) (PS), Trios 3 (3Shape) (T3), Trios 4 (3Shape) (T4), and CS3600 (Carestream Dentistry) (CS)) captured digital implant impressions with and without additional RO. Scans were aligned and assessed for distance and angulation measurements between scan bodies. Statistical analyses compared trueness and precision across model groups using the Student t-test and Welch's ANOVA. RESULTS CS consistently showed the highest distance values across IOS devices in both the 4-U and 3-U models (P < .05), both with and without RO. The distance values were not considerably affected by the presence of RO (P > .05), except for a few isolated cases in the PS and CS groups of 3-U models. When measuring angles, CS usually showed greater values than the other IOS devices, especially when RO was present both in the 4-U and 3-U variants (P < .05). CONCLUSION The influence of additional reference objects on accuracy varies with different scanner types, irrespective of edentulous area length.

Zurich Open Repository and Archive (University of Zurich)
Openalex Percentile: Top 58%
Ecology and Vegetation Dynamics Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of reference objects on the accuracy of digital implant impressions in partially edentulous arches · Zurich Open Repository and Archive (University of Zurich) (2024) | TGRS Research Map | TGRS