Correlates and Comparability of Two Devices for Measuring Bite Force in Dentate Health Volunteers

OBJECTIVE This study aimed to correlate the bite/occlusal force measurements obtained through two methods: a hydraulic pressure gauge with a biting transducer (GM-10), and a computer-assisted device that records occlusal force on a pressure-sensitive film (Prescale II). METHODS Healthy, dentate volunteers were recruited. Participants' demographic data included age, sex, number of teeth present, presence of oral pain, history of prior orthodontic treatment and presence of parafunction. Bite/occlusal force measurements were recorded for each participant using the GM-10 and the Prescale II devices. Linear Mixed-effect model regression was performed with the significance set at p < 0.05. RESULTS Forty-six volunteers (women = 25, men = 21; mean-age = 30.9 ± 9.3 years) participated. 54.3% and 34.8% presented with 28 and 29-32 teeth, respectively. 60.9% and 26.1% of the participants reported previous orthodontic treatment and oral parafunction. The overall mean GM-10 measurements recorded were 333.0 ± 192, 276 ± 167, 208 ± 134, 142 ± 103 Newtons, for the 2nd and 1st molars, 2nd and 1st premolars, respectively. GM-10 measurements were associated with the tooth position (p < 0.001) and the number of teeth (p < 0.001). The mean Prescale II measurements obtained with and without filter were 826 ± 594 and 1049 ± 595 Newtons, respectively, which were positively correlated with the occlusal contact area (r = 0.765; p < 0.001) and GM-10 (r = 0.245; p = 0.019). The regression analysis for dependent repeated data confirmed the significant effect of the GM-10 measurements (bite force) and the occlusal contact area on the Prescale II measurements. CONCLUSION Within the limitations of this study, it can be concluded that the correlation between bite force measurements carried out by GM-10 and Dental Prescale II was low and may not be considered interchangeable methods. The maximum bite force measured in isolated point contacts was a predictive factor of the occlusal force distributed over the entire arch. Further studies are warranted to explore this influence in the clinical implications of these findings.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2025-03-01
DOI
https://doi.org/10.5167/uzh-267750
Primary Topic
Parasitic Infections and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlates and Comparability of Two Devices for Measuring Bite Force in Dentate Health Volunteers

Zurich Open Repository and Archive (University of Zurich)
Parasitic Infections and Diagnostics
article

Correlates and Comparability of Two Devices for Measuring Bite Force in Dentate Health Volunteers

article en

Abstract

OBJECTIVE This study aimed to correlate the bite/occlusal force measurements obtained through two methods: a hydraulic pressure gauge with a biting transducer (GM-10), and a computer-assisted device that records occlusal force on a pressure-sensitive film (Prescale II). METHODS Healthy, dentate volunteers were recruited. Participants' demographic data included age, sex, number of teeth present, presence of oral pain, history of prior orthodontic treatment and presence of parafunction. Bite/occlusal force measurements were recorded for each participant using the GM-10 and the Prescale II devices. Linear Mixed-effect model regression was performed with the significance set at p < 0.05. RESULTS Forty-six volunteers (women = 25, men = 21; mean-age = 30.9 ± 9.3 years) participated. 54.3% and 34.8% presented with 28 and 29-32 teeth, respectively. 60.9% and 26.1% of the participants reported previous orthodontic treatment and oral parafunction. The overall mean GM-10 measurements recorded were 333.0 ± 192, 276 ± 167, 208 ± 134, 142 ± 103 Newtons, for the 2nd and 1st molars, 2nd and 1st premolars, respectively. GM-10 measurements were associated with the tooth position (p < 0.001) and the number of teeth (p < 0.001). The mean Prescale II measurements obtained with and without filter were 826 ± 594 and 1049 ± 595 Newtons, respectively, which were positively correlated with the occlusal contact area (r = 0.765; p < 0.001) and GM-10 (r = 0.245; p = 0.019). The regression analysis for dependent repeated data confirmed the significant effect of the GM-10 measurements (bite force) and the occlusal contact area on the Prescale II measurements. CONCLUSION Within the limitations of this study, it can be concluded that the correlation between bite force measurements carried out by GM-10 and Dental Prescale II was low and may not be considered interchangeable methods. The maximum bite force measured in isolated point contacts was a predictive factor of the occlusal force distributed over the entire arch. Further studies are warranted to explore this influence in the clinical implications of these findings.

Zurich Open Repository and Archive (University of Zurich)
Good health and well-being
Openalex Percentile: Top 52%
Parasitic Infections and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.