Simplified meal announcement study (SMASH) using hybrid closed-loop insulin delivery in youth and young adults with type 1 diabetes: a randomised controlled two-centre crossover trial.

Aims/hypothesis The majority of hybrid closed-loop systems still require carbohydrate counting (CC) but the evidence for its justification remains limited. Here, we evaluated glucose control with simplified meal announcement (SMA) vs CC in youth and young adults with type 1 diabetes using the mylife CamAPS FX system.Methods We conducted a two-centre, randomised crossover, non-inferiority trial in two University Hospitals in Switzerland in 46 participants (aged 12-20 years) with type 1 diabetes using multiple daily injections (n=35), sensor-augmented pump (n=4) or hybrid closed-loop (n=7) therapy before enrolment. Participants underwent two 3 month periods with the mylife CamAPS FX system (YpsoPump, Dexcom G6) to compare SMA (individualised carbohydrate meal sizes) with CC, in a randomly assigned order using computer-generated sequences. The primary endpoint was the proportion of time glucose was in target range (3.9-10.0 mmol/l) with a non-inferiority margin of 5 percentage points. Secondary endpoints were other sensor glucose and insulin metrics, usability and safety endpoints.Results Forty-three participants (18 women and girls) completed the trial. In the intention-to-treat analysis, time in range (mean±SD) was 69.9±12.4% with SMA and 70.7±13.0% with CC (estimated mean difference -0.6 percentage points [95% CI -2.4, 1.1], demonstrating non-inferiority). Time <3.9 mmol/l (median [IQR] 1.8 [1.2-2.2]% vs 1.9 [1.6-2.5]%) and >10.0 mmol/l (28.2±12.6% vs 27.2±13.4%) was similar between periods. Total daily insulin dose was higher with SMA (54.0±14.7 U vs 51.7±12.1 U, p=0.037). Three participants experienced serious adverse events, none of which were intervention-related.Conclusions/interpretation Glucose control using the CamAPS FX algorithm with SMA was non-inferior to its use with CC in youth and young adults with type 1 diabetes.Trial Registration ClinicalTrials.gov NCT05481034.Funding The study was supported by the Swiss Diabetes Foundation and by a YTCR grant from the Bangerter-Rhyner Foundation and the Swiss Academy of Medical Sciences. Dexcom and Ypsomed provided product support.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-12-02
DOI
https://doi.org/10.48620/77062
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simplified meal announcement study (SMASH) using hybrid closed-loop insulin delivery in youth and young adults with type 1 diabetes: a randomised controlled two-centre crossover trial.

Open Access CRIS of the University of Bern
Diabetes Management and Research
article

Simplified meal announcement study (SMASH) using hybrid closed-loop insulin delivery in youth and young adults with type 1 diabetes: a randomised controlled two-centre crossover trial.

article en

Abstract

Aims/hypothesis The majority of hybrid closed-loop systems still require carbohydrate counting (CC) but the evidence for its justification remains limited. Here, we evaluated glucose control with simplified meal announcement (SMA) vs CC in youth and young adults with type 1 diabetes using the mylife CamAPS FX system.Methods We conducted a two-centre, randomised crossover, non-inferiority trial in two University Hospitals in Switzerland in 46 participants (aged 12-20 years) with type 1 diabetes using multiple daily injections (n=35), sensor-augmented pump (n=4) or hybrid closed-loop (n=7) therapy before enrolment. Participants underwent two 3 month periods with the mylife CamAPS FX system (YpsoPump, Dexcom G6) to compare SMA (individualised carbohydrate meal sizes) with CC, in a randomly assigned order using computer-generated sequences. The primary endpoint was the proportion of time glucose was in target range (3.9-10.0 mmol/l) with a non-inferiority margin of 5 percentage points. Secondary endpoints were other sensor glucose and insulin metrics, usability and safety endpoints.Results Forty-three participants (18 women and girls) completed the trial. In the intention-to-treat analysis, time in range (mean±SD) was 69.9±12.4% with SMA and 70.7±13.0% with CC (estimated mean difference -0.6 percentage points [95% CI -2.4, 1.1], demonstrating non-inferiority). Time <3.9 mmol/l (median [IQR] 1.8 [1.2-2.2]% vs 1.9 [1.6-2.5]%) and >10.0 mmol/l (28.2±12.6% vs 27.2±13.4%) was similar between periods. Total daily insulin dose was higher with SMA (54.0±14.7 U vs 51.7±12.1 U, p=0.037). Three participants experienced serious adverse events, none of which were intervention-related.Conclusions/interpretation Glucose control using the CamAPS FX algorithm with SMA was non-inferior to its use with CC in youth and young adults with type 1 diabetes.Trial Registration ClinicalTrials.gov NCT05481034.Funding The study was supported by the Swiss Diabetes Foundation and by a YTCR grant from the Bangerter-Rhyner Foundation and the Swiss Academy of Medical Sciences. Dexcom and Ypsomed provided product support.

Open Access CRIS of the University of Bern
Diabetes Australia (AU)
Openalex Percentile: Top 52%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simplified meal announcement study (SMASH) using hybrid closed-loop insulin delivery in youth and young adults with type 1 diabetes: a randomised controlled two-centre crossover trial. · Open Access CRIS of the University of Bern (2024) | TGRS Research Map | TGRS