Stability of Hemolytic, Lipemic, and Icteric Indices in Blood Samples Transported by Drone: A Focused Report.

Background Maintaining blood sample integrity is essential for accurate laboratory diagnostics. The hemolytic, lipemic, and icteric (HIL) indices are critical markers of sample quality, detecting common preanalytical interferences such as hemolysis, lipemia, and icterus. Drone technology offers a novel transport method for medical logistics, particularly in remote or underserved regions. This study assessed the stability of HIL indices in blood samples transported by drone.Methods Twenty-five samples each of serum, EDTA whole blood, lithium-heparin plasma, and citrate plasma were collected from healthy volunteers using standard venipuncture techniques. Serum samples were collected in gel separator tubes. Samples were transported unprocessed using a rotor-type hybrid drone (Jedsy Glider) over a 25-kilometer route. Temperature and vibration were monitored during flight using data loggers and accelerometers. HIL indices were measured preflight and postflight using a Roche Cobas 6000 system. Paired t-tests assessed significant changes (P < 0.05).Results No statistically significant differences were observed in the HIL indices preflight and postflight for all blood sample types. For serum samples, the hemolytic index decreased slightly from 9.60 to 9.45 (P = 0.19), with negligible changes in lipemic and icteric indices. Similar stability was observed for EDTA whole blood, lithium-heparin plasma, and citrate plasma.Conclusions Drone transport is a viable alternative for blood sample logistics, preserving HIL index stability across various sample types. These findings underscore the potential of drones to enhance healthcare logistics in remote or underserved environments.Research Ethics This study was conducted as a quality assurance project for the Institute of Clinical Chemistry at Dr. Risch, Buchs, Switzerland. The Ethics Committee Ostschweiz reviewed the study under BASEC-ID Req-2024-01510 and determined that it does not fall within the scope of the Swiss Human Research Act and therefore does not require formal ethics committee approval. This determination was based on the project's designation as a quality assurance initiative rather than a human research study. As per the committee's guidance, data protection and confidentiality were strictly maintained throughout the study, ensuring compliance with all relevant legal and institutional requirements.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-04-22
DOI
https://doi.org/10.48620/87403
Primary Topic
Molecular Biology Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability of Hemolytic, Lipemic, and Icteric Indices in Blood Samples Transported by Drone: A Focused Report.

Open Access CRIS of the University of Bern
Molecular Biology Techniques and Applications
article

Stability of Hemolytic, Lipemic, and Icteric Indices in Blood Samples Transported by Drone: A Focused Report.

article en

Abstract

Background Maintaining blood sample integrity is essential for accurate laboratory diagnostics. The hemolytic, lipemic, and icteric (HIL) indices are critical markers of sample quality, detecting common preanalytical interferences such as hemolysis, lipemia, and icterus. Drone technology offers a novel transport method for medical logistics, particularly in remote or underserved regions. This study assessed the stability of HIL indices in blood samples transported by drone.Methods Twenty-five samples each of serum, EDTA whole blood, lithium-heparin plasma, and citrate plasma were collected from healthy volunteers using standard venipuncture techniques. Serum samples were collected in gel separator tubes. Samples were transported unprocessed using a rotor-type hybrid drone (Jedsy Glider) over a 25-kilometer route. Temperature and vibration were monitored during flight using data loggers and accelerometers. HIL indices were measured preflight and postflight using a Roche Cobas 6000 system. Paired t-tests assessed significant changes (P < 0.05).Results No statistically significant differences were observed in the HIL indices preflight and postflight for all blood sample types. For serum samples, the hemolytic index decreased slightly from 9.60 to 9.45 (P = 0.19), with negligible changes in lipemic and icteric indices. Similar stability was observed for EDTA whole blood, lithium-heparin plasma, and citrate plasma.Conclusions Drone transport is a viable alternative for blood sample logistics, preserving HIL index stability across various sample types. These findings underscore the potential of drones to enhance healthcare logistics in remote or underserved environments.Research Ethics This study was conducted as a quality assurance project for the Institute of Clinical Chemistry at Dr. Risch, Buchs, Switzerland. The Ethics Committee Ostschweiz reviewed the study under BASEC-ID Req-2024-01510 and determined that it does not fall within the scope of the Swiss Human Research Act and therefore does not require formal ethics committee approval. This determination was based on the project's designation as a quality assurance initiative rather than a human research study. As per the committee's guidance, data protection and confidentiality were strictly maintained throughout the study, ensuring compliance with all relevant legal and institutional requirements.

Open Access CRIS of the University of Bern
Partnerships for the goals
Openalex Percentile: Top 58%
Molecular Biology Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Stability of Hemolytic, Lipemic, and Icteric Indices in Blood Samples Transported by Drone: A Focused Report. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS