Profile line accuracy in cephalometric radiographs.

Introduction This study investigates the accuracy of facial soft-tissue profile lines in lateral cephalometric radiographs by comparing them to true profile lines derived from 3-dimensional photographs.Methods This prospective methodological study was performed on preexisting records of 100 orthodontic patients. The true profiles were obtained by defining the true midsagittal plane through best-fit approximation of mirrored 3-dimensional surface models. Two curves were drawn on each profile image, and landmarks and sliding semilandmarks were placed on them. This resulted in 2 profile landmark configurations per patient, which were superimposed using Procrustes superimposition. The Procrustes distances between corresponding landmarks were used as a metric to assess the accuracy of the cephalometric profile line, as compared with the true reference.Results On average, there were small statistically significant differences between the cephalometric and the actual profile lines (100,000 permutations; P = 0.031; median interlandmark distance, 0.84 mm). However, when assessing individual patients, the cephalometric profile line deviated significantly from the true profile, with 40% of the distances between corresponding landmarks being >1 mm and 10% being >2 mm. There were no differences between the sexes or between younger and older patients (aged 8.0-12.5 vs 12.5-55.0 years). However, there were small differences between 2 x-ray devices (median, 0.18 mm; P <0.001), which often exceeded 1 mm at the soft-tissue nasion area, probably because of the cephalostat.Conclusions On average, the lateral cephalometric radiographs might provide an adequate representation of the facial profile, but when individual patients are considered, there is often a clinically significant error. Thus, lateral cephalograms should be used with caution to evaluate the facial soft-tissue profile.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-04-02
DOI
https://doi.org/10.48620/86950
Primary Topic
Gaussian Processes and Bayesian Inference
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Profile line accuracy in cephalometric radiographs.

Open Access CRIS of the University of Bern
Gaussian Processes and Bayesian Inference
article

Profile line accuracy in cephalometric radiographs.

article en

Abstract

Introduction This study investigates the accuracy of facial soft-tissue profile lines in lateral cephalometric radiographs by comparing them to true profile lines derived from 3-dimensional photographs.Methods This prospective methodological study was performed on preexisting records of 100 orthodontic patients. The true profiles were obtained by defining the true midsagittal plane through best-fit approximation of mirrored 3-dimensional surface models. Two curves were drawn on each profile image, and landmarks and sliding semilandmarks were placed on them. This resulted in 2 profile landmark configurations per patient, which were superimposed using Procrustes superimposition. The Procrustes distances between corresponding landmarks were used as a metric to assess the accuracy of the cephalometric profile line, as compared with the true reference.Results On average, there were small statistically significant differences between the cephalometric and the actual profile lines (100,000 permutations; P = 0.031; median interlandmark distance, 0.84 mm). However, when assessing individual patients, the cephalometric profile line deviated significantly from the true profile, with 40% of the distances between corresponding landmarks being >1 mm and 10% being >2 mm. There were no differences between the sexes or between younger and older patients (aged 8.0-12.5 vs 12.5-55.0 years). However, there were small differences between 2 x-ray devices (median, 0.18 mm; P <0.001), which often exceeded 1 mm at the soft-tissue nasion area, probably because of the cephalostat.Conclusions On average, the lateral cephalometric radiographs might provide an adequate representation of the facial profile, but when individual patients are considered, there is often a clinically significant error. Thus, lateral cephalograms should be used with caution to evaluate the facial soft-tissue profile.

Open Access CRIS of the University of Bern
Govt. Dental College & Hospital (IN)
Openalex Percentile: Top 76%
Gaussian Processes and Bayesian Inference
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.