A Usability Pilot Study of a Sensor-Guided Interactive System for Dexterity Training in Parkinson's Disease.

This pilot study aimed to evaluate the usability of a new, feedback-based dexterity training system in people with Parkinson's disease (PwPD) and healthy adults. Seven PwPD and seven healthy adults participated in the study. The System Usability Scale (SUS) and the Post-Study System Usability Questionnaire Version 3 (PSSUQ) were used to assess usability. Additionally, the feedback shown as a counter, detected through newly developed algorithms, was evaluated by comparing the device-detected repetitions during six exercises to those counted by a supervisor. High median SUS scores of 92.5 were obtained in both PwPD (IQR = 81.25-98.75) and healthy adults (IQR = 87.5-93.75, maximum score 100, minimum score 0). Similarly, high PSSUQ median scores were achieved after the session (1.14, IQR = 1.00-1.33, PD; 1.08, IQR = 1.00-1.58, healthy adults, maximum score 1, minimum score 7). PwPD completed 648 repetitions, with 551 (85%) correctly recognized by the system. For healthy adults, 883 out of 913 (97%) repetitions were classified as right. The present study showed high usability and high perceived user satisfaction for the new training system in all study participants. The system effectively detects exercise repetition rates but requires further refinement to enhance accuracy for specific pinch grip exercises.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-02-10
DOI
https://doi.org/10.48620/85895
Primary Topic
Semiconductor Quantum Structures and Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Usability Pilot Study of a Sensor-Guided Interactive System for Dexterity Training in Parkinson's Disease.

Open Access CRIS of the University of Bern
Semiconductor Quantum Structures and Devices
article

A Usability Pilot Study of a Sensor-Guided Interactive System for Dexterity Training in Parkinson's Disease.

article en

Abstract

This pilot study aimed to evaluate the usability of a new, feedback-based dexterity training system in people with Parkinson's disease (PwPD) and healthy adults. Seven PwPD and seven healthy adults participated in the study. The System Usability Scale (SUS) and the Post-Study System Usability Questionnaire Version 3 (PSSUQ) were used to assess usability. Additionally, the feedback shown as a counter, detected through newly developed algorithms, was evaluated by comparing the device-detected repetitions during six exercises to those counted by a supervisor. High median SUS scores of 92.5 were obtained in both PwPD (IQR = 81.25-98.75) and healthy adults (IQR = 87.5-93.75, maximum score 100, minimum score 0). Similarly, high PSSUQ median scores were achieved after the session (1.14, IQR = 1.00-1.33, PD; 1.08, IQR = 1.00-1.58, healthy adults, maximum score 1, minimum score 7). PwPD completed 648 repetitions, with 551 (85%) correctly recognized by the system. For healthy adults, 883 out of 913 (97%) repetitions were classified as right. The present study showed high usability and high perceived user satisfaction for the new training system in all study participants. The system effectively detects exercise repetition rates but requires further refinement to enhance accuracy for specific pinch grip exercises.

Open Access CRIS of the University of Bern
National Center for Geriatrics and Gerontology (JP)
Openalex Percentile: Top 59%
Semiconductor Quantum Structures and Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.