ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG

Hospitals are significant producers of liquid waste that have the potential to pollute the environment if not properly managed. Hospital wastewater contains organic and inorganic substances, pathogenic microorganisms, and hazardous chemicals. This study aims to evaluate the effectiveness of the Wastewater Treatment Plant (WWTP) at Bhayangkara Hospital Kupang based on chemical and microbiological parameters, including pH, temperature, Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), Total Dissolved Solids (TDS), oil and grease, and total coliform. The study uses a descriptive qualitative method with secondary data analysis from laboratory results. The results show that all parameters are below the threshold of environmental quality standards set by the Ministry of Environment Regulation No. 5 of 2014, with values for: pH (7.255), temperature (28°C), BOD (38.7 mg/L), COD (76 mg/L), TSS (0.06 mg/L), TDS (363 mg/L), oil and grease (0.016 mg/L), and total coliform (438/100 mL). These results indicate that the WWTP at Bhayangkara Hospital Kupang operates effectively in treating wastewater, making the discharged wastewater suitable for disposal into the environment and in compliance with the established quality standards.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.47668/edusaintek.v12i3.1789
Primary Topic
Meta-analysis and systematic reviews
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG

SHILAP Revista de lepidopterología
Meta-analysis and systematic reviews
article

ANALISIS EFEKTIVITAS PENGELOLAAN AIR LIMBAH RUMAH SAKIT BHAYANGKARA KUPANG

article en

Abstract

Hospitals are significant producers of liquid waste that have the potential to pollute the environment if not properly managed. Hospital wastewater contains organic and inorganic substances, pathogenic microorganisms, and hazardous chemicals. This study aims to evaluate the effectiveness of the Wastewater Treatment Plant (WWTP) at Bhayangkara Hospital Kupang based on chemical and microbiological parameters, including pH, temperature, Biological Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), Total Dissolved Solids (TDS), oil and grease, and total coliform. The study uses a descriptive qualitative method with secondary data analysis from laboratory results. The results show that all parameters are below the threshold of environmental quality standards set by the Ministry of Environment Regulation No. 5 of 2014, with values for: pH (7.255), temperature (28°C), BOD (38.7 mg/L), COD (76 mg/L), TSS (0.06 mg/L), TDS (363 mg/L), oil and grease (0.016 mg/L), and total coliform (438/100 mL). These results indicate that the WWTP at Bhayangkara Hospital Kupang operates effectively in treating wastewater, making the discharged wastewater suitable for disposal into the environment and in compliance with the established quality standards.

SHILAP Revista de lepidopterología
Encana (Canada) (CA)
Clean water and sanitation
Openalex Percentile: Top 55%
Meta-analysis and systematic reviews
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.