A Direct-Digital 40 μA 100 kb/s Intracardiac Communication Receiver with 250 μs Startup Time for Low Duty-Cycle Leadless Pacemaker Synchronization

The first commercial dual-chamber leadless pacemaker (LLPM) was introduced recently. The system combines two separate implants situated in the right atrium and the right ventricle of the heart. Implant synchronization is accomplished with conductive intracardiac communication (CIC) using the myocardium and blood as transmission channel. Successful implant synchronization of this dual-chamber LLPM has been demonstrated. However, the continuously active synchronization transceivers, consuming about 800 nA, cause a 25-45% reduction in the projected device longevity. This work proposes an alternative strategy for power-optimized LLPM synchronization, which is based on synchronous duty-cycling of the transceivers and direct-digital CIC (DD-CIC). In line with this strategy, a novel low-power DD-CIC receiver for short-packet communication based on Manchester-encoded data and with fast startup time is presented. The circuit was fabricated in 180 nm CMOS technology and analyzed with respect to sensitivity, current consumption and startup time under highly duty-cycled operation. The receiver achieves a sensitivity of 81.6±7.4 μV at a data rate of 100 kb/s, with an active current consumption of 39.1±0.6 μA and a startup time below 250 μs. Operating the receiver as specified by the proposed LLPM synchronization strategy reduces the current consumption to a measured average value of 73 nA. In conclusion, this work suggests synchronous duty-cycling for CIC-based implant synchronization as a promising concept to severely reduce the current consumption of contemporary dual-chamber LLPMs. Consequently, device longevity may be increased significantly, potentially reducing the frequency of costly and complication-prone re-interventions.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2024-12-01
DOI
https://doi.org/10.48620/77104
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Direct-Digital 40 μA 100 kb/s Intracardiac Communication Receiver with 250 μs Startup Time for Low Duty-Cycle Leadless Pacemaker Synchronization

Open Access CRIS of the University of Bern
Cardiac pacing and defibrillation studies
article

A Direct-Digital 40 μA 100 kb/s Intracardiac Communication Receiver with 250 μs Startup Time for Low Duty-Cycle Leadless Pacemaker Synchronization

article en

Abstract

The first commercial dual-chamber leadless pacemaker (LLPM) was introduced recently. The system combines two separate implants situated in the right atrium and the right ventricle of the heart. Implant synchronization is accomplished with conductive intracardiac communication (CIC) using the myocardium and blood as transmission channel. Successful implant synchronization of this dual-chamber LLPM has been demonstrated. However, the continuously active synchronization transceivers, consuming about 800 nA, cause a 25-45% reduction in the projected device longevity. This work proposes an alternative strategy for power-optimized LLPM synchronization, which is based on synchronous duty-cycling of the transceivers and direct-digital CIC (DD-CIC). In line with this strategy, a novel low-power DD-CIC receiver for short-packet communication based on Manchester-encoded data and with fast startup time is presented. The circuit was fabricated in 180 nm CMOS technology and analyzed with respect to sensitivity, current consumption and startup time under highly duty-cycled operation. The receiver achieves a sensitivity of 81.6±7.4 μV at a data rate of 100 kb/s, with an active current consumption of 39.1±0.6 μA and a startup time below 250 μs. Operating the receiver as specified by the proposed LLPM synchronization strategy reduces the current consumption to a measured average value of 73 nA. In conclusion, this work suggests synchronous duty-cycling for CIC-based implant synchronization as a promising concept to severely reduce the current consumption of contemporary dual-chamber LLPMs. Consequently, device longevity may be increased significantly, potentially reducing the frequency of costly and complication-prone re-interventions.

Open Access CRIS of the University of Bern
Precision for Medicine (United States) (US), Ophthalmology Clinic (DE), Precision Research (United States) (US)
Affordable and clean energy
Openalex Percentile: Top 48%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Direct-Digital 40 μA 100 kb/s Intracardiac Communication Receiver with 250 μs Startup Time for Low Duty-Cycle Leadless Pacemaker Synchronization · Open Access CRIS of the University of Bern (2024) | TGRS Research Map | TGRS