Evaluating Wideband Tympanometry Absorbance Changes in Cochlear Implant Recipients: Mechanical Insights and Influencing Parameters

Background: Cochlear implant (CI) electrode insertion can change the mechanical state of the ear whereby wideband tympanometry absorbance (WBTA) may serve as a sensitive tool to monitor these mechanical changes of the peripheral auditory pathway after CI surgery. In WBTA, the amount of acoustic energy reflected by the tympanic membrane is assessed over a wide frequency range from 226 Hz to 8000 Hz. The objective of this study was to monitor changes in WBTA in CI recipients before and after surgery. Methods: Following otoscopy, WBTA measurements were conducted twice in both ears of 38 standard CI recipients before and in the range of 4 to 15 weeks after CI implantation. Changes from pre- to postoperative absorbance patterns were compared for the implanted as well as the contralateral control ear for six different frequencies (500 Hz, 750 Hz, 1000 Hz, 2000 Hz, 3000 Hz, 4000 Hz). Furthermore, the influence of the time point of the measurement, surgical access, electrode type, sex and side of the implantation were assessed for the implanted and the control ear in a linear mixed model. Results: A significant decrease in WBTA could be observed in the implanted ear when compared with the contralateral control ear for 750 Hz (p < 0.01) and 1000 Hz (p < 0.05). The typical two-peak pattern of WBTA measurements was seen in both ears preoperatively but changed to a one-peak pattern in the newly implanted ear. The linear mixed model showed that not only the cochlear implantation in general but also the insertion through the round window compared to the cochleostomy leads to a decreased absorbance at 750 and 1000 Hz. Conclusions: With WBTA, we were able to detect mechanical changes of the acoustical pathway after CI surgery. The implantation of a CI led to decreased absorbance in the lower frequencies and the two-peak pattern was shifted to a one-peak pattern. The result of the linear mixed model indicates that WBTA can detect mechanical changes due to cochlear implantation not only in the middle ear but also in the inner ear.

Publication Details

Journal
Zurich Open Repository and Archive (University of Zurich)
Published
2024-08-29
DOI
https://doi.org/10.5167/uzh-262502
Primary Topic
Renin-Angiotensin System Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Wideband Tympanometry Absorbance Changes in Cochlear Implant Recipients: Mechanical Insights and Influencing Parameters

Zurich Open Repository and Archive (University of Zurich)
Renin-Angiotensin System Studies
article

Evaluating Wideband Tympanometry Absorbance Changes in Cochlear Implant Recipients: Mechanical Insights and Influencing Parameters

article en

Abstract

Background: Cochlear implant (CI) electrode insertion can change the mechanical state of the ear whereby wideband tympanometry absorbance (WBTA) may serve as a sensitive tool to monitor these mechanical changes of the peripheral auditory pathway after CI surgery. In WBTA, the amount of acoustic energy reflected by the tympanic membrane is assessed over a wide frequency range from 226 Hz to 8000 Hz. The objective of this study was to monitor changes in WBTA in CI recipients before and after surgery. Methods: Following otoscopy, WBTA measurements were conducted twice in both ears of 38 standard CI recipients before and in the range of 4 to 15 weeks after CI implantation. Changes from pre- to postoperative absorbance patterns were compared for the implanted as well as the contralateral control ear for six different frequencies (500 Hz, 750 Hz, 1000 Hz, 2000 Hz, 3000 Hz, 4000 Hz). Furthermore, the influence of the time point of the measurement, surgical access, electrode type, sex and side of the implantation were assessed for the implanted and the control ear in a linear mixed model. Results: A significant decrease in WBTA could be observed in the implanted ear when compared with the contralateral control ear for 750 Hz (p < 0.01) and 1000 Hz (p < 0.05). The typical two-peak pattern of WBTA measurements was seen in both ears preoperatively but changed to a one-peak pattern in the newly implanted ear. The linear mixed model showed that not only the cochlear implantation in general but also the insertion through the round window compared to the cochleostomy leads to a decreased absorbance at 750 and 1000 Hz. Conclusions: With WBTA, we were able to detect mechanical changes of the acoustical pathway after CI surgery. The implantation of a CI led to decreased absorbance in the lower frequencies and the two-peak pattern was shifted to a one-peak pattern. The result of the linear mixed model indicates that WBTA can detect mechanical changes due to cochlear implantation not only in the middle ear but also in the inner ear.

Zurich Open Repository and Archive (University of Zurich)
Openalex Percentile: Top 48%
Renin-Angiotensin System Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.