Photon-Counting CT-Angiography to Assess Intracranial Stents and Flow Diverters in Comparison to Digital Subtraction Angiography.

Purpose Photon-Counting Detector CT is characterized by enhanced image post-processing capabilities. The diagnostic accuracy of PCD-CT angiography (PCD-CTA) in assessing intracranial stents (ICS) and flow diverters (FD) has yet to be compared with digital subtraction angiography (DSA).Methods Retrospective analysis of all consecutive patients who underwent ICS or FD implantation between April 2023 and May 2024. Polyenergetic images, along with virtual monoenergetic imaging (VMI), pure lumen (PL) and iodine (IOD) reconstructions were assessed by three readers using a 5-point Likert scale and defined regions of interest (ROIs). A blinded analysis was performed to identify relevant lumen reduction. The diagnostic accuracy of PCD-CTA was compared to DSA by calculating the area under the receiver operating characteristic curve.Results A total of 18 patients (mean age 59 ± 13 years; 14 women) with 14 implanted ICS and 10 FD were analyzed. Across all pairwise comparisons, pooled VMI reconstructions demonstrated higher ratings and signal-to-noise ratios compared to IOD, PL and UHR reconstructions (p < 0.001 for all comparisons). In the pooled assessment of DSA of in-stent vessel lumen 18 (11%) of the 162 vessel segments and 6 (33%) of the 18 patients presented relevant narrowing of the in-stent vessel lumen. The sensitivity of PCD-CTA for detecting stenosis was 100% (18 of 18 in-stent vessel segments), while specificity was 89% (128/144 in-stent vessel segments). All readers reported a 100% negative predictive value (128/128 in-stent vessel segments).Conclusion Photon-Counting Detector CT might provide a reliable assessment of intracranial vessels following stent or flow diverter implantation comparable to DSA in many cases.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-05-16
DOI
https://doi.org/10.48620/88088
Primary Topic
HIV/AIDS Research and Interventions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photon-Counting CT-Angiography to Assess Intracranial Stents and Flow Diverters in Comparison to Digital Subtraction Angiography.

Open Access CRIS of the University of Bern
HIV/AIDS Research and Interventions
article

Photon-Counting CT-Angiography to Assess Intracranial Stents and Flow Diverters in Comparison to Digital Subtraction Angiography.

article en

Abstract

Purpose Photon-Counting Detector CT is characterized by enhanced image post-processing capabilities. The diagnostic accuracy of PCD-CT angiography (PCD-CTA) in assessing intracranial stents (ICS) and flow diverters (FD) has yet to be compared with digital subtraction angiography (DSA).Methods Retrospective analysis of all consecutive patients who underwent ICS or FD implantation between April 2023 and May 2024. Polyenergetic images, along with virtual monoenergetic imaging (VMI), pure lumen (PL) and iodine (IOD) reconstructions were assessed by three readers using a 5-point Likert scale and defined regions of interest (ROIs). A blinded analysis was performed to identify relevant lumen reduction. The diagnostic accuracy of PCD-CTA was compared to DSA by calculating the area under the receiver operating characteristic curve.Results A total of 18 patients (mean age 59 ± 13 years; 14 women) with 14 implanted ICS and 10 FD were analyzed. Across all pairwise comparisons, pooled VMI reconstructions demonstrated higher ratings and signal-to-noise ratios compared to IOD, PL and UHR reconstructions (p < 0.001 for all comparisons). In the pooled assessment of DSA of in-stent vessel lumen 18 (11%) of the 162 vessel segments and 6 (33%) of the 18 patients presented relevant narrowing of the in-stent vessel lumen. The sensitivity of PCD-CTA for detecting stenosis was 100% (18 of 18 in-stent vessel segments), while specificity was 89% (128/144 in-stent vessel segments). All readers reported a 100% negative predictive value (128/128 in-stent vessel segments).Conclusion Photon-Counting Detector CT might provide a reliable assessment of intracranial vessels following stent or flow diverter implantation comparable to DSA in many cases.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 49%
HIV/AIDS Research and Interventions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Photon-Counting CT-Angiography to Assess Intracranial Stents and Flow Diverters in Comparison to Digital Subtraction Angiography. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS