Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes

Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.

Publication Details

Journal
Repository for Publications and Research Data (ETH Zurich)
Published
2025-04-01
DOI
https://doi.org/10.3929/ethz-b-000729675
Primary Topic
Monoclonal and Polyclonal Antibodies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes

Repository for Publications and Research Data (ETH Zurich)
Monoclonal and Polyclonal Antibodies Research
article

Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes

article en

Abstract

Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.

Repository for Publications and Research Data (ETH Zurich)
Good health and well-being
Openalex Percentile: Top 41%
Monoclonal and Polyclonal Antibodies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes · Repository for Publications and Research Data (ETH Zurich) (2025) | TGRS Research Map | TGRS