Impact of temperature on the PDIV of induction motor turn insulation analogy in dry air

This work investigates the impact of temperature on the partial discharge inception voltage (PDIV) of an induction motor turn insulation analogy in dry air. This analogy consist of a pair of contacting aluminum electrodes coated with a ≈60–80 µm-thick layer of polymer. Based on a previously published breakdown prediction model and references found in the literature, the PDIV variance due to temperature is assumed to be mainly affected by the coating's relative permittivity—a function of temperature and test voltage frequency—and the density of ambient air. To separate and investigate these effects individually, perfluoroalkoxy alkane (PFA) and polyamide (PA) coatings are used. The relative permittivity of PFA is almost invariant to both temperature and frequency within the ranges examined in the work (25 ∘C–105 ∘C and 10–50 000 Hz, respectively), whereas PA's shows a substantial dependence on both. PDIV and PD extinction voltage (PDEV) values obtained from measurements over the temperature and frequency ranges are compared to predictions obtained from the breakdown model and good agreement with a maximum deviation of 100 V (peak) is obtained for the PA samples. For PFA samples, measurement challenges and substantial differences between the PDIV and the corresponding PDEV due to PFA's characteristic properties are discussed. In view of these limitations, the agreement between the model and the experiment is also considered satisfactory for PFA. The provided model, which considers only thermally-induced changes in the coating's permittivity and air density, is regarded as suitable for predicting the PDIV in systems similar to the turn insulation of induction motors, under the influence of temperature and assuming negligible ambient air humidity.

Publication Details

Journal
Repository for Publications and Research Data (ETH Zurich)
Published
2025-03-17
DOI
https://doi.org/10.3929/ethz-b-000716597
Primary Topic
Healthcare and Environmental Waste Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of temperature on the PDIV of induction motor turn insulation analogy in dry air

Repository for Publications and Research Data (ETH Zurich)
Healthcare and Environmental Waste Management
article

Impact of temperature on the PDIV of induction motor turn insulation analogy in dry air

article en

Abstract

This work investigates the impact of temperature on the partial discharge inception voltage (PDIV) of an induction motor turn insulation analogy in dry air. This analogy consist of a pair of contacting aluminum electrodes coated with a ≈60–80 µm-thick layer of polymer. Based on a previously published breakdown prediction model and references found in the literature, the PDIV variance due to temperature is assumed to be mainly affected by the coating's relative permittivity—a function of temperature and test voltage frequency—and the density of ambient air. To separate and investigate these effects individually, perfluoroalkoxy alkane (PFA) and polyamide (PA) coatings are used. The relative permittivity of PFA is almost invariant to both temperature and frequency within the ranges examined in the work (25 ∘C–105 ∘C and 10–50 000 Hz, respectively), whereas PA's shows a substantial dependence on both. PDIV and PD extinction voltage (PDEV) values obtained from measurements over the temperature and frequency ranges are compared to predictions obtained from the breakdown model and good agreement with a maximum deviation of 100 V (peak) is obtained for the PA samples. For PFA samples, measurement challenges and substantial differences between the PDIV and the corresponding PDEV due to PFA's characteristic properties are discussed. In view of these limitations, the agreement between the model and the experiment is also considered satisfactory for PFA. The provided model, which considers only thermally-induced changes in the coating's permittivity and air density, is regarded as suitable for predicting the PDIV in systems similar to the turn insulation of induction motors, under the influence of temperature and assuming negligible ambient air humidity.

Repository for Publications and Research Data (ETH Zurich)
Openalex Percentile: Top 43%
Healthcare and Environmental Waste Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of temperature on the PDIV of induction motor turn insulation analogy in dry air · Repository for Publications and Research Data (ETH Zurich) (2025) | TGRS Research Map | TGRS