Comparison of Methods of µ-Map Generation: MR-Based Method in PET/MR Imaging Versus Pseudo-CT Method in Radiotherapy Dose Planning

Introduction: Attenuation correction is essential for accurate PET imaging and radiotherapy (RT) dose planning. However, PET/MR systems face a significant challenge due to the lack of direct attenuation data from MR images, unlike PET/CT where CT provides inherent attenuation information. Similarly, the increasing use of MRI in RT planning necessitates pseudo-CT methods for accurate dose calculation. This study compares MR-based µ-map generation for PET/MR and pseudo-CT methods for RT planning, addressing their challenges and limitations to improve treatment accuracy and patient care. Material and Methods: The study involved patient selection, image processing, and generation of MR-based attenuation maps (µ-maps) for PET attenuation correction and pseudo-CTs for RT dose planning using advanced computational software. Results: MR-based µ-maps, potentially useful for PET attenuation correction, and pseudo CTs, potentially applicable in radiotherapy planning, were successfully generated. Head images showed MR-based µ-maps overestimating bone for two patients (deviations of 4.0% and 4.2%). Both MR-based and CT µ-maps exhibited dynamic and continuous µ-values for head bone. In the pelvis, pseudo-CT underestimated bone volume in five patients (deviations of 18.7%, 21.3%, 9.6%, 14%, and 10%). Pseudo-CT's bone µ-values lacked continuity compared to CT µ-maps. Pelvis studies revealed more dynamic and broader µ-value range for muscle in CT µ-maps than pseudo-CT and MRI µ-map. Conclusion: These findings suggest the need for careful consideration and validation of attenuation correction methods, especially in regions with complex anatomical structures, to ensure accurate treatment delivery and enhance patient care in the context of PET/MR and radiotherapy.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.22038/ijmp.2024.77457.2369
Primary Topic
Microbial Natural Products and Biosynthesis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Methods of µ-Map Generation: MR-Based Method in PET/MR Imaging Versus Pseudo-CT Method in Radiotherapy Dose Planning

SHILAP Revista de lepidopterología
Microbial Natural Products and Biosynthesis
article

Comparison of Methods of µ-Map Generation: MR-Based Method in PET/MR Imaging Versus Pseudo-CT Method in Radiotherapy Dose Planning

article en

Abstract

Introduction: Attenuation correction is essential for accurate PET imaging and radiotherapy (RT) dose planning. However, PET/MR systems face a significant challenge due to the lack of direct attenuation data from MR images, unlike PET/CT where CT provides inherent attenuation information. Similarly, the increasing use of MRI in RT planning necessitates pseudo-CT methods for accurate dose calculation. This study compares MR-based µ-map generation for PET/MR and pseudo-CT methods for RT planning, addressing their challenges and limitations to improve treatment accuracy and patient care. Material and Methods: The study involved patient selection, image processing, and generation of MR-based attenuation maps (µ-maps) for PET attenuation correction and pseudo-CTs for RT dose planning using advanced computational software. Results: MR-based µ-maps, potentially useful for PET attenuation correction, and pseudo CTs, potentially applicable in radiotherapy planning, were successfully generated. Head images showed MR-based µ-maps overestimating bone for two patients (deviations of 4.0% and 4.2%). Both MR-based and CT µ-maps exhibited dynamic and continuous µ-values for head bone. In the pelvis, pseudo-CT underestimated bone volume in five patients (deviations of 18.7%, 21.3%, 9.6%, 14%, and 10%). Pseudo-CT's bone µ-values lacked continuity compared to CT µ-maps. Pelvis studies revealed more dynamic and broader µ-value range for muscle in CT µ-maps than pseudo-CT and MRI µ-map. Conclusion: These findings suggest the need for careful consideration and validation of attenuation correction methods, especially in regions with complex anatomical structures, to ensure accurate treatment delivery and enhance patient care in the context of PET/MR and radiotherapy.

SHILAP Revista de lepidopterología
University of Education, Winneba (GH), University of Health and Allied Sciences (GH), Ghana Atomic Energy Commission (GH)
Openalex Percentile: Top 60%
Microbial Natural Products and Biosynthesis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.