A short-circuit current calculation method for direct-driven wind farms based on voltage iteration

Short-circuit current calculations for wind farms typically employ equivalent models that neglect internal lines, transformers, and other critical factors, leading to reduced accuracy. Methods that account for these factors often rely on simultaneous voltage and current iteration, which complicates the intuitive verification of convergence. To address such issues, this paper proposes a short-circuit current calculation method that incorporates the internal structural parameters of wind farms. Based on the current characteristics of direct-driven permanent magnet synchronous generators (D-PMSG) under current-limiting conditions and the equations for the maximum node voltage of wind farm, a calculation model for short-circuit current in a wind farm is built. Then, Norton equivalence is applied to eliminate unknown current parameters, and the modified node voltage equation based on varying operating conditions is established. Finally, by implementing voltage iteration, a modified short-circuit current calculation method based on the modified model and the characteristics of the wind farm is obtained. Simulation comparisons demonstrate that the proposed method offers enhanced accuracy and improved convergence.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.19585/j.zjdl.202410008
Primary Topic
Software System Performance and Reliability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A short-circuit current calculation method for direct-driven wind farms based on voltage iteration

SHILAP Revista de lepidopterología
Software System Performance and Reliability
article

A short-circuit current calculation method for direct-driven wind farms based on voltage iteration

article en

Abstract

Short-circuit current calculations for wind farms typically employ equivalent models that neglect internal lines, transformers, and other critical factors, leading to reduced accuracy. Methods that account for these factors often rely on simultaneous voltage and current iteration, which complicates the intuitive verification of convergence. To address such issues, this paper proposes a short-circuit current calculation method that incorporates the internal structural parameters of wind farms. Based on the current characteristics of direct-driven permanent magnet synchronous generators (D-PMSG) under current-limiting conditions and the equations for the maximum node voltage of wind farm, a calculation model for short-circuit current in a wind farm is built. Then, Norton equivalence is applied to eliminate unknown current parameters, and the modified node voltage equation based on varying operating conditions is established. Finally, by implementing voltage iteration, a modified short-circuit current calculation method based on the modified model and the characteristics of the wind farm is obtained. Simulation comparisons demonstrate that the proposed method offers enhanced accuracy and improved convergence.

SHILAP Revista de lepidopterología
Affordable and clean energy
Openalex Percentile: Top 56%
Software System Performance and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.