An optimal protection scheme for spatially distributed UHVDC transmission systems

Spatially distributed UHVDC transmission systems eliminate the need for AC transmission lines converging at a converter station by enabling DC power transmission at remote locations. However, this change in topology introduces new challenges for DC protection. To address protection failure in the operating station after faults occur in the bipolar neutral bus area and grounding electrode line area of low-end nonoperational station, improved protection criteria are proposed based on theoretical analysis and simulation tests. Additionally, the shortcomings of existing fault isolation measures for grounding faults on the low-voltage side of the DC filter at the high-end terminal are analyzed, and a fault isolation scheme for the DC filter is proposed. Finally, the characteristics of differential protection in the DC field are examined, and optimal protection criteria are introduced and validated using real-time digital simulation (RTDS) system.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.19585/j.zjdl.202504001
Primary Topic
Occupational Health and Global Justice
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An optimal protection scheme for spatially distributed UHVDC transmission systems

SHILAP Revista de lepidopterología
Occupational Health and Global Justice
article

An optimal protection scheme for spatially distributed UHVDC transmission systems

article en

Abstract

Spatially distributed UHVDC transmission systems eliminate the need for AC transmission lines converging at a converter station by enabling DC power transmission at remote locations. However, this change in topology introduces new challenges for DC protection. To address protection failure in the operating station after faults occur in the bipolar neutral bus area and grounding electrode line area of low-end nonoperational station, improved protection criteria are proposed based on theoretical analysis and simulation tests. Additionally, the shortcomings of existing fault isolation measures for grounding faults on the low-voltage side of the DC filter at the high-end terminal are analyzed, and a fault isolation scheme for the DC filter is proposed. Finally, the characteristics of differential protection in the DC field are examined, and optimal protection criteria are introduced and validated using real-time digital simulation (RTDS) system.

SHILAP Revista de lepidopterología
China Electric Equipment Group (China) (CN)
Openalex Percentile: Top 46%
Occupational Health and Global Justice
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.