Design of a Synchrotron for Proton FLASH Radiotherapy Based on Fast Variable-Energy Bunch Splitting

Ultra-high dose rate (FLASH) radiotherapy not only guarantees effective tumor treatment but also greatly enhances the protection of normal tissue. Moreover, it is a convenient procedure for tumor patients that has enhanced the benefits provided by medical institutions. Proton FLASH radiotherapy, which combines the Bragg peak effect of proton spatial dose distribution with the unique temporal effect advantage of FLASH, is an attractive tumor treatment approach. To achieve proton FLASH discrete pencil beam scanning in a 1-L volume, taking into account the 5-mm point interval, 9261 points would need to be irradiated within 500 ms, which is beyond the capability of existing medical devices. To meet these requirements, based on a fast cycle synchrotron with a period of 25 Hz, we simultaneously combined variable-energy, fast splitting, and extraction beam bunches, and proposed a scanning method suitable for continuous variable-energy extraction bunches. The proposed technique meet the requirements of proton FLASH discrete pencil beam scanning within a volume of 1 L.

Institutions

Publication Details

Journal
JACOW
Published
2025-05-22
DOI
https://doi.org/10.18429/jacow-sap2023-tupb026
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a Synchrotron for Proton FLASH Radiotherapy Based on Fast Variable-Energy Bunch Splitting

JACOW
Advanced Electron Microscopy Techniques and Applications
article

Design of a Synchrotron for Proton FLASH Radiotherapy Based on Fast Variable-Energy Bunch Splitting

article en

Abstract

Ultra-high dose rate (FLASH) radiotherapy not only guarantees effective tumor treatment but also greatly enhances the protection of normal tissue. Moreover, it is a convenient procedure for tumor patients that has enhanced the benefits provided by medical institutions. Proton FLASH radiotherapy, which combines the Bragg peak effect of proton spatial dose distribution with the unique temporal effect advantage of FLASH, is an attractive tumor treatment approach. To achieve proton FLASH discrete pencil beam scanning in a 1-L volume, taking into account the 5-mm point interval, 9261 points would need to be irradiated within 500 ms, which is beyond the capability of existing medical devices. To meet these requirements, based on a fast cycle synchrotron with a period of 25 Hz, we simultaneously combined variable-energy, fast splitting, and extraction beam bunches, and proposed a scanning method suitable for continuous variable-energy extraction bunches. The proposed technique meet the requirements of proton FLASH discrete pencil beam scanning within a volume of 1 L.

JACOW
State Council of the People's Republic of China (CN)
Affordable and clean energy
Openalex Percentile: Top 74%
Advanced Electron Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.