Transparent and flexible patient-specific aneurysm models for device testing

Patient-specific intracranial aneurysm models play a pivotal role in the in vitro evaluation of endovascular devices. To enable robust testing and reflect physiological conditions, these models must be optically transparent, anatomically accurate, mechanically stable, and elastic. This study explores a multi-material, variable-thickness fabrication strategy using stereolithography 3D-printing (SLA) to optimize medical IA. IA models were constructed by [1]: a) segmenting vessels from medical radiological images (region growing, marching cube’s algorithms, MevisLab, MeVis Medical solution); b) manual correction of segmentation errors; c) addition of vessel wall and flow connectors; d) 3D printing (Form 3, Formlabs). A Clear V4 Resin (Material-1, Formlabs) was used to produce transparent models. The initial vessel wall was uniform with a thickness of 3 mm and offered sufficient structural durability. However, the optical visibility through the model was suboptimal. A modified design strategy was introduced, implementing a localized wall thickness reduction (?1 mm) at the aneurysmal sac while retaining thicker walls (3 mm) otherwise. This approach preserved model integrity during mechanical handling and connection to experimental circuits while enhancing visibility in regions critical for evaluating the efficiency of the endovascular devices. In addition, two elastomeric SLA materials (Formlabs), Elastic 50A (Material-2) and Flexible 80A (Material-3), at various wall thicknesses (1.0 mm, 0.8 mm, and 0.4 mm) were evaluated to mimic the biomechanical properties of human vasculature. Models produced with Material-2 were more transparent than Material-1 and -3 but failed to maintain form stability, especially at 0.4 mm. Material-3 improved tear resistance compared to Material-2 at 0.8 mm, albeit with reduced optical clarity. The investigation of Material-3 with 0.4 mm vessel wall thickness is ongoing. Wall thickness and material modifications can be used to balance transparency and mechanical performance. The proposed fabrication strategy supports the development of anatomically accurate, optically clear, and mechanically robust models for use in in vitro testing of endovascular devices.

Institutions

Publication Details

Journal
Infinite Science GmbH
Published
2025-05-20
DOI
https://doi.org/10.18416/ammm.2025.25062418
Primary Topic
Economic and Technological Innovation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transparent and flexible patient-specific aneurysm models for device testing

Infinite Science GmbH
Economic and Technological Innovation
article

Transparent and flexible patient-specific aneurysm models for device testing

article en

Abstract

Patient-specific intracranial aneurysm models play a pivotal role in the in vitro evaluation of endovascular devices. To enable robust testing and reflect physiological conditions, these models must be optically transparent, anatomically accurate, mechanically stable, and elastic. This study explores a multi-material, variable-thickness fabrication strategy using stereolithography 3D-printing (SLA) to optimize medical IA. IA models were constructed by [1]: a) segmenting vessels from medical radiological images (region growing, marching cube’s algorithms, MevisLab, MeVis Medical solution); b) manual correction of segmentation errors; c) addition of vessel wall and flow connectors; d) 3D printing (Form 3, Formlabs). A Clear V4 Resin (Material-1, Formlabs) was used to produce transparent models. The initial vessel wall was uniform with a thickness of 3 mm and offered sufficient structural durability. However, the optical visibility through the model was suboptimal. A modified design strategy was introduced, implementing a localized wall thickness reduction (?1 mm) at the aneurysmal sac while retaining thicker walls (3 mm) otherwise. This approach preserved model integrity during mechanical handling and connection to experimental circuits while enhancing visibility in regions critical for evaluating the efficiency of the endovascular devices. In addition, two elastomeric SLA materials (Formlabs), Elastic 50A (Material-2) and Flexible 80A (Material-3), at various wall thicknesses (1.0 mm, 0.8 mm, and 0.4 mm) were evaluated to mimic the biomechanical properties of human vasculature. Models produced with Material-2 were more transparent than Material-1 and -3 but failed to maintain form stability, especially at 0.4 mm. Material-3 improved tear resistance compared to Material-2 at 0.8 mm, albeit with reduced optical clarity. The investigation of Material-3 with 0.4 mm vessel wall thickness is ongoing. Wall thickness and material modifications can be used to balance transparency and mechanical performance. The proposed fabrication strategy supports the development of anatomically accurate, optically clear, and mechanically robust models for use in in vitro testing of endovascular devices.

Infinite Science GmbH
Rincon Research (United States) (US)
Openalex Percentile: Top 45%
Economic and Technological Innovation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Transparent and flexible patient-specific aneurysm models for device testing · Infinite Science GmbH (2025) | TGRS Research Map | TGRS