Development and Evaluation of a 3D–Printed Adapter for Docking Hohmann Retractors to Weitlaner Retractors; Constructing Failure: A SCOT Analysis of Modular Titanium Alloy Neck Adapter (MTANA) Breakdowns in Hip Replacement Systems

The development of medical devices sits at a complex intersection where engineering design meets human factors, institutional constraints, and diverse stakeholder priorities. My technical project and STS research paper explore complementary perspectives on this relationship. While my technical work focused on creating a novel 3D-printed adapter to improve surgical workflow in Orthopaedic procedures, my STS research examined how competing interpretations of "success" among different stakeholders contributed to the failure of Modular Titanium Alloy Neck Adapters (MTANAs) in hip replacement systems. The connection between these projects lies in their shared exploration of how technical design choices and sociotechnical factors influence the ultimate success or failure of medical devices. My technical project involves the development and evaluation of a 3D-printed adapter designed to dock the Hohmann retractor onto the Weitlaner retractor during Orthopaedic procedures. The posterolateral approach for open reduction and internal fixation (ORIF) of fractures typically requires multiple surgical assistants to maintain proper tissue retraction. Our adapter addresses this challenge by enabling hands-free retraction, potentially improving surgical efficiency and reducing dependency on additional staff. Through an iterative design process, we developed prototypes using Autodesk Fusion and tested them in both simulated environments and cadaveric specimens. Material selection proved critical, with Nylon PA12 emerging as the optimal choice due to its balance of tensile strength, sterilization compatibility, and cost-effectiveness. Feedback from Orthopaedic professionals indicated that the adapter was easy to use, provided stable retraction, and could potentially save significant time during procedures. My STS research paper employed Wiebe Bijker and Trevor Pinch's Social Construction of Technology (SCOT) framework to analyze the failure of MTANAs in hip replacement systems between 2004 and 2013. I argued that the MTANA crisis emerged not from isolated engineering miscalculations, but from the co-construction of risk by three relevant social groups: surgeons who prioritized intraoperative flexibility over long-term biomechanics, manufacturers who leveraged modularity for market differentiation, and regulators who applied inappropriate equivalence standards to novel material configurations. The paper examined how the interpretative flexibility of "success" among these stakeholders permitted the widespread adoption of a fundamentally unstable implant. The SCOT analysis revealed how competing priorities and power dynamics shaped the trajectory of this medical technology, demonstrating that technologies stabilize not because they are objectively safe but because powerful institutional players define problems and solutions in ways that suppress disconfirming evidence. My STS research on MTANAs heightened my awareness of how different stakeholders' priorities can influence device adoption, sometimes at the expense of safety. This understanding directly informed my technical work, where I carefully balanced the needs of surgeons (ease of use, workflow efficiency) with material considerations and patient safety concerns. Conversely, the practical challenges of my technical project—navigating material constraints, user preferences, and regulatory requirements—gave me concrete experience with the sociotechnical negotiations I was analyzing theoretically in my STS research. Both projects reinforced that successful medical device design requires not just technical excellence but also an understanding of how devices function within complex sociotechnical systems where success is socially constructed through the interaction of diverse stakeholders with different values and priorities.

Institutions

Publication Details

Journal
Libra
Published
2025-05-09
DOI
https://doi.org/10.18130/1022-n006
Primary Topic
Iron Metabolism and Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Evaluation of a 3D–Printed Adapter for Docking Hohmann Retractors to Weitlaner Retractors; Constructing Failure: A SCOT Analysis of Modular Titanium Alloy Neck Adapter (MTANA) Breakdowns in Hip Replacement Systems

Libra
Iron Metabolism and Disorders
article

Development and Evaluation of a 3D–Printed Adapter for Docking Hohmann Retractors to Weitlaner Retractors; Constructing Failure: A SCOT Analysis of Modular Titanium Alloy Neck Adapter (MTANA) Breakdowns in Hip Replacement Systems

article en

Abstract

The development of medical devices sits at a complex intersection where engineering design meets human factors, institutional constraints, and diverse stakeholder priorities. My technical project and STS research paper explore complementary perspectives on this relationship. While my technical work focused on creating a novel 3D-printed adapter to improve surgical workflow in Orthopaedic procedures, my STS research examined how competing interpretations of "success" among different stakeholders contributed to the failure of Modular Titanium Alloy Neck Adapters (MTANAs) in hip replacement systems. The connection between these projects lies in their shared exploration of how technical design choices and sociotechnical factors influence the ultimate success or failure of medical devices. My technical project involves the development and evaluation of a 3D-printed adapter designed to dock the Hohmann retractor onto the Weitlaner retractor during Orthopaedic procedures. The posterolateral approach for open reduction and internal fixation (ORIF) of fractures typically requires multiple surgical assistants to maintain proper tissue retraction. Our adapter addresses this challenge by enabling hands-free retraction, potentially improving surgical efficiency and reducing dependency on additional staff. Through an iterative design process, we developed prototypes using Autodesk Fusion and tested them in both simulated environments and cadaveric specimens. Material selection proved critical, with Nylon PA12 emerging as the optimal choice due to its balance of tensile strength, sterilization compatibility, and cost-effectiveness. Feedback from Orthopaedic professionals indicated that the adapter was easy to use, provided stable retraction, and could potentially save significant time during procedures. My STS research paper employed Wiebe Bijker and Trevor Pinch's Social Construction of Technology (SCOT) framework to analyze the failure of MTANAs in hip replacement systems between 2004 and 2013. I argued that the MTANA crisis emerged not from isolated engineering miscalculations, but from the co-construction of risk by three relevant social groups: surgeons who prioritized intraoperative flexibility over long-term biomechanics, manufacturers who leveraged modularity for market differentiation, and regulators who applied inappropriate equivalence standards to novel material configurations. The paper examined how the interpretative flexibility of "success" among these stakeholders permitted the widespread adoption of a fundamentally unstable implant. The SCOT analysis revealed how competing priorities and power dynamics shaped the trajectory of this medical technology, demonstrating that technologies stabilize not because they are objectively safe but because powerful institutional players define problems and solutions in ways that suppress disconfirming evidence. My STS research on MTANAs heightened my awareness of how different stakeholders' priorities can influence device adoption, sometimes at the expense of safety. This understanding directly informed my technical work, where I carefully balanced the needs of surgeons (ease of use, workflow efficiency) with material considerations and patient safety concerns. Conversely, the practical challenges of my technical project—navigating material constraints, user preferences, and regulatory requirements—gave me concrete experience with the sociotechnical negotiations I was analyzing theoretically in my STS research. Both projects reinforced that successful medical device design requires not just technical excellence but also an understanding of how devices function within complex sociotechnical systems where success is socially constructed through the interaction of diverse stakeholders with different values and priorities.

Libra
University of Virginia (US)
Openalex Percentile: Top 36%
Iron Metabolism and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.