Short Term Air Conditioning System Configuration Scheme for Subway Station in Hot Summer and Warm Winter Areas

[Objective] There are significant differences between the air conditioning system loads of subway stations in short term and long term. In order to avoid serious operation energy waste, the air conditioning system configuration mainly adopts variable frequency scheme or phased configuration scheme, but systematic quantitative research are still required. Therefore, it is necessary to study the air conditioning system configuration scheme for subway station operations in the short term. [Method] Taking a typical subway station in a city with hot summers and warm winters as an example, a load and energy consumption model that can analyze the superposed impact of actual engineering problems is established, and the model is corrected using actual test data. Two commonly used configuration schemes for air conditioning systems in subway station short-term operation are compared, and the operating energy consumption of the two schemes and the reasons for their differences are calculated and analyzed. [Result & Conclusion] Under ideal working conditions, i.e. the installed capacity of the equipment meets the actual load requirements and the air conditioning system is operated in variable frequency, scheme Ⅱ (phased configuration scheme) could save 19.7% energy compared to scheme Ⅰ (variable frequency scheme) ; under the most unfavorable working conditions, i.e. the installed capacity of the equipment is 50% greater than the actual load demand and the equipment frequency is not fully variable in operation, Scheme Ⅱ could save 42.1% energy compared with Scheme Ⅰ. When adopting Scheme Ⅰ, the installed capacity of the equipment should be closer to the actual load, and reasonable self-control strategies and variable frequency equipment should be adopted to ensure that the air conditioning system can be adjusted according to the actual load. When adopting Scheme Ⅱ, the resistance of the water and wind systems should be carefully calculated in the design.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.16037/j.1007-869x.2025.04.015
Primary Topic
Plant nutrient uptake and metabolism
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short Term Air Conditioning System Configuration Scheme for Subway Station in Hot Summer and Warm Winter Areas

SHILAP Revista de lepidopterología
Plant nutrient uptake and metabolism
article

Short Term Air Conditioning System Configuration Scheme for Subway Station in Hot Summer and Warm Winter Areas

article en

Abstract

[Objective] There are significant differences between the air conditioning system loads of subway stations in short term and long term. In order to avoid serious operation energy waste, the air conditioning system configuration mainly adopts variable frequency scheme or phased configuration scheme, but systematic quantitative research are still required. Therefore, it is necessary to study the air conditioning system configuration scheme for subway station operations in the short term. [Method] Taking a typical subway station in a city with hot summers and warm winters as an example, a load and energy consumption model that can analyze the superposed impact of actual engineering problems is established, and the model is corrected using actual test data. Two commonly used configuration schemes for air conditioning systems in subway station short-term operation are compared, and the operating energy consumption of the two schemes and the reasons for their differences are calculated and analyzed. [Result & Conclusion] Under ideal working conditions, i.e. the installed capacity of the equipment meets the actual load requirements and the air conditioning system is operated in variable frequency, scheme Ⅱ (phased configuration scheme) could save 19.7% energy compared to scheme Ⅰ (variable frequency scheme) ; under the most unfavorable working conditions, i.e. the installed capacity of the equipment is 50% greater than the actual load demand and the equipment frequency is not fully variable in operation, Scheme Ⅱ could save 42.1% energy compared with Scheme Ⅰ. When adopting Scheme Ⅰ, the installed capacity of the equipment should be closer to the actual load, and reasonable self-control strategies and variable frequency equipment should be adopted to ensure that the air conditioning system can be adjusted according to the actual load. When adopting Scheme Ⅱ, the resistance of the water and wind systems should be carefully calculated in the design.

SHILAP Revista de lepidopterología
Shanghai Tongji Urban Planning and Design Institute (CN), Beijing University of Civil Engineering and Architecture (CN), Tsinghua University (CN)
Affordable and clean energy
Openalex Percentile: Top 67%
Plant nutrient uptake and metabolism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.