Corrosion Behavior of Low Temperature Rolled and Annealed CrCoNi Medium Entropy Alloys in 3.5%NaCl Solution

In order to study the corrosion resistance of low-temperature rolled and annealed CrCoNi medium entropy alloy in NaCl solution, the CrCoNi medium entropy alloy deformed by low-temperature (-196 ℃) rolling was annealed at 800 ℃for 30 min.The corrosion resistance of low-temperature rolled and annealed samples in 3.5%(mass fraction) NaCl solution was characterized and analyzed by metallographic microscope, transmission electron microscope, atomic force microscope, photoelectron spectrometer, electrochemical workstation and other testing methods.Results showed that the corrosion resistance of low-temperature rolled samples was poor.After annealing at 800 ℃for 30 min, the corrosion resistance of the samples was significantly improved.Owing to the recrystallization behavior of the rolled state alloy after annealing,grain refinement occurred, and the content of Cr2O3 and Cr(OH)3 in the passivation film on the alloy surface increased, thereby improving the corrosion resistance of the alloy.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.16577/j.issn.1001-1560.2024.0199
Primary Topic
High Entropy Alloys Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion Behavior of Low Temperature Rolled and Annealed CrCoNi Medium Entropy Alloys in 3.5%NaCl Solution

SHILAP Revista de lepidopterología
High Entropy Alloys Studies
article

Corrosion Behavior of Low Temperature Rolled and Annealed CrCoNi Medium Entropy Alloys in 3.5%NaCl Solution

article en

Abstract

In order to study the corrosion resistance of low-temperature rolled and annealed CrCoNi medium entropy alloy in NaCl solution, the CrCoNi medium entropy alloy deformed by low-temperature (-196 ℃) rolling was annealed at 800 ℃for 30 min.The corrosion resistance of low-temperature rolled and annealed samples in 3.5%(mass fraction) NaCl solution was characterized and analyzed by metallographic microscope, transmission electron microscope, atomic force microscope, photoelectron spectrometer, electrochemical workstation and other testing methods.Results showed that the corrosion resistance of low-temperature rolled samples was poor.After annealing at 800 ℃for 30 min, the corrosion resistance of the samples was significantly improved.Owing to the recrystallization behavior of the rolled state alloy after annealing,grain refinement occurred, and the content of Cr2O3 and Cr(OH)3 in the passivation film on the alloy surface increased, thereby improving the corrosion resistance of the alloy.

SHILAP Revista de lepidopterología
Panzhihua University (CN)
Openalex Percentile: Top 66%
High Entropy Alloys Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Corrosion Behavior of Low Temperature Rolled and Annealed CrCoNi Medium Entropy Alloys in 3.5%NaCl Solution · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS