Analysis of Accuracy Related Factors in Photon Counting X-ray CT Energy Imaging

Multi-energy spectrum imaging with photon counting detectors has become the focus of X-ray imaging. In this study, the Geant4 simulation software was used to generate the energy spectrum of the ray source, obtaining high-low energy spectra of different ranges by setting different detector energy resolutions and changing the energy threshold. High-low energy projection data of scan objects were obtained for dual-energy reconstruction. The standard deviation of the effective atomic number and electron density under each group were compared. The results show that the higher the energy resolution and the greater the difference between high and low energy spectra, the better is the imaging quality. The energy threshold influenced the imaging accuracy when the spectrum overlap ratio was changed. When the spectrum overlap became smaller and the spectral width became narrower, noise increased, making it necessary to balance the relationship between spectrum overlap and noise to achieve better imaging results.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.15953/j.ctta.2024.254
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Accuracy Related Factors in Photon Counting X-ray CT Energy Imaging

SHILAP Revista de lepidopterología
Advanced X-ray and CT Imaging
article

Analysis of Accuracy Related Factors in Photon Counting X-ray CT Energy Imaging

article en

Abstract

Multi-energy spectrum imaging with photon counting detectors has become the focus of X-ray imaging. In this study, the Geant4 simulation software was used to generate the energy spectrum of the ray source, obtaining high-low energy spectra of different ranges by setting different detector energy resolutions and changing the energy threshold. High-low energy projection data of scan objects were obtained for dual-energy reconstruction. The standard deviation of the effective atomic number and electron density under each group were compared. The results show that the higher the energy resolution and the greater the difference between high and low energy spectra, the better is the imaging quality. The energy threshold influenced the imaging accuracy when the spectrum overlap ratio was changed. When the spectrum overlap became smaller and the spectral width became narrower, noise increased, making it necessary to balance the relationship between spectrum overlap and noise to achieve better imaging results.

SHILAP Revista de lepidopterología
China Machine Press (CN)
Affordable and clean energy
Openalex Percentile: Top 56%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Accuracy Related Factors in Photon Counting X-ray CT Energy Imaging · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS