Ultratrace Gold in High-Purity Graphite by High-Resolution Continuous Light Source Graphite Furnace Atomic Absorption Spectrometry with Hanging Droplet Microextraction

The major challenge in accurately determining ultratrace gold in high-purity graphite is how to achieve effective separation and high enrichment of it (0.1−1ng/mL) in the sample solution, while minimizing the secondary pollution introduced by vessels, reagents, materials, environment, and equipment during the sample pretreatment process. A new method for the analysis of ultratrace gold in high-purity graphite is established by ashing and acid dissolution in a platinum dish, followed by microextraction with a hanging droplet of tributyl phosphate. Firstly, the fixed carbon in the sample was removed by high-temperature burning in a platinum vessel; then, the ash was completely dissolved into a sample solution using hydrofluoric acid-aqua regia-perchloric acid; next, micro-upgraded tributyl phosphate droplets were used as an extractant to separate and enrich gold from the sample solution; finally, gold in the droplets was determined using high-resolution continuum source graphite furnace atomic absorption spectrometry. The experimental results showed that by using 2.5μL of tributyl phosphate (chloroform volume fraction 20%) as the extractant, gold can be extracted from a sample solution in 10% hydrochloric acid medium for 2min, and the enrichment factor for gold can reach up to 283 times. Under the selected experimental conditions, the mass concentration of gold showed a good linear relationship with its absorbance values in the range of 0.1 to 2.0ng/mL. The correlation coefficient (r) was 0.999, and the detection limit of the method was 0.11ng/g. Interference tests showed that the presence of certain coexisting elements such as sodium, magnesium, and aluminum in the sample solution had no effect on the determination of gold. According to the experimental method, the gold content in five high-purity graphite samples was measured. The relative standard deviation (RSD, n=6) of the results was 1.5%−4.9%, and the recovery rate was 94.9%−105.3%.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.15898/j.ykcs.202406210137
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultratrace Gold in High-Purity Graphite by High-Resolution Continuous Light Source Graphite Furnace Atomic Absorption Spectrometry with Hanging Droplet Microextraction

1 citations
SHILAP Revista de lepidopterología
Analytical chemistry methods development
0.24
article

Ultratrace Gold in High-Purity Graphite by High-Resolution Continuous Light Source Graphite Furnace Atomic Absorption Spectrometry with Hanging Droplet Microextraction

article en
1 citations

Abstract

The major challenge in accurately determining ultratrace gold in high-purity graphite is how to achieve effective separation and high enrichment of it (0.1−1ng/mL) in the sample solution, while minimizing the secondary pollution introduced by vessels, reagents, materials, environment, and equipment during the sample pretreatment process. A new method for the analysis of ultratrace gold in high-purity graphite is established by ashing and acid dissolution in a platinum dish, followed by microextraction with a hanging droplet of tributyl phosphate. Firstly, the fixed carbon in the sample was removed by high-temperature burning in a platinum vessel; then, the ash was completely dissolved into a sample solution using hydrofluoric acid-aqua regia-perchloric acid; next, micro-upgraded tributyl phosphate droplets were used as an extractant to separate and enrich gold from the sample solution; finally, gold in the droplets was determined using high-resolution continuum source graphite furnace atomic absorption spectrometry. The experimental results showed that by using 2.5μL of tributyl phosphate (chloroform volume fraction 20%) as the extractant, gold can be extracted from a sample solution in 10% hydrochloric acid medium for 2min, and the enrichment factor for gold can reach up to 283 times. Under the selected experimental conditions, the mass concentration of gold showed a good linear relationship with its absorbance values in the range of 0.1 to 2.0ng/mL. The correlation coefficient (r) was 0.999, and the detection limit of the method was 0.11ng/g. Interference tests showed that the presence of certain coexisting elements such as sodium, magnesium, and aluminum in the sample solution had no effect on the determination of gold. According to the experimental method, the gold content in five high-purity graphite samples was measured. The relative standard deviation (RSD, n=6) of the results was 1.5%−4.9%, and the recovery rate was 94.9%−105.3%.

SHILAP Revista de lepidopterología
Chinese Academy of Geological Sciences (CN)
Openalex Percentile: Top 47%
Analytical chemistry methods development
0.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.