Inclusivity in global research.

<div><p>This study aimed to determine the validity and between-day reliability of the mean velocity (MV), peak velocity (PV), mean power (MP), and peak power (PP) provided by the Vitruve linear position transducer at different submaximal loads in the free-weight and Smith machine back squat using GymAware as a reference point. Fourteen male sports science students (free-weight back squat one-repetition maximum [1RM]: 132.5 ± 28.5 kg, Smith machine back squat 1RM: 163.9 ± 30.4 kg) performed six experimental sessions, twice per week with 72 hours of rest. The first two included the assessment of the 1RM of both exercises. In the four remaining, both linear position transducers were simultaneously used to record MV, PV, MP, PP of each repetition during an incremental load test (i.e., 20, 40, 60, 80, 90% 1RM) with three minutes of rest between sets. Vitruve displayed both fixed and proportional bias for certain relative loads across all variables. Vitruve did not meet the validity criteria for all (MV, PP) or at least two (MP, PV) relative loads (Coefficient of variation [CV] > 10%; Pearson correlation < 0.70; Effect size > 0.60). MV, PV, MP, and PP recorded by Vitruve displayed acceptable reliability (CV < 10%) with superior reliability observed during a Smith Machine compared to free-weight back squat, and for velocity compared to power variables. Considering GymAware as a reference point, Vitruve was not valid for measuring velocity and power outcomes. Acceptable validity was observed only for PV in the Smith machine back squat, while the other variables—regardless of relative loads and exercise modes—were mostly inaccurate. All variables demonstrated acceptable reliability, with greater reliability noted in the Smith machine compared to the free-weight back squat exercise mode.</p></div>

Publication Details

Journal
Figshare
Published
2024-10-24
DOI
https://doi.org/10.1371/journal.pone.0312348.s001
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inclusivity in global research.

Figshare
Sports Performance and Training
article

Inclusivity in global research.

article en

Abstract

<div><p>This study aimed to determine the validity and between-day reliability of the mean velocity (MV), peak velocity (PV), mean power (MP), and peak power (PP) provided by the Vitruve linear position transducer at different submaximal loads in the free-weight and Smith machine back squat using GymAware as a reference point. Fourteen male sports science students (free-weight back squat one-repetition maximum [1RM]: 132.5 ± 28.5 kg, Smith machine back squat 1RM: 163.9 ± 30.4 kg) performed six experimental sessions, twice per week with 72 hours of rest. The first two included the assessment of the 1RM of both exercises. In the four remaining, both linear position transducers were simultaneously used to record MV, PV, MP, PP of each repetition during an incremental load test (i.e., 20, 40, 60, 80, 90% 1RM) with three minutes of rest between sets. Vitruve displayed both fixed and proportional bias for certain relative loads across all variables. Vitruve did not meet the validity criteria for all (MV, PP) or at least two (MP, PV) relative loads (Coefficient of variation [CV] > 10%; Pearson correlation < 0.70; Effect size > 0.60). MV, PV, MP, and PP recorded by Vitruve displayed acceptable reliability (CV < 10%) with superior reliability observed during a Smith Machine compared to free-weight back squat, and for velocity compared to power variables. Considering GymAware as a reference point, Vitruve was not valid for measuring velocity and power outcomes. Acceptable validity was observed only for PV in the Smith machine back squat, while the other variables—regardless of relative loads and exercise modes—were mostly inaccurate. All variables demonstrated acceptable reliability, with greater reliability noted in the Smith machine compared to the free-weight back squat exercise mode.</p></div>

Figshare
Openalex Percentile: Top 57%
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Inclusivity in global research. · Figshare (2024) | TGRS Research Map | TGRS