Assay validation with temperature gradient and standard curve.

Assay development consisted of a temperature gradient approach on standard samples of DNA extracted from <i>Chondria tumulosa</i> tissue and no-template controls (NTC) to monitor for contamination. (a) The ideal annealing temperature (54.7–64°C) was selected among triplicate amplifications that produced a sigmoidal curve in the fewest cycles. (b) Melt curves were verified to only produce a single tall, narrow peak. (c) Threshold cycle (C<sub>q</sub>) values are plotted against triplicate DNA serial dilution starting concentrations to generate a best fit standard curve (R<sup>2</sup> = 0.999, slope = -3.79, intercept = 33.62), using the curve-fitting approach [<a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0318414#pone.0318414.ref063" target="_blank">63</a>]. Synthetic <i>C</i>. <i>tumulosa</i> DNA was quantified using a fluorometer (Qubit, Invitrogen) and diluted to create 10-fold serial dilutions ranging from 10<sup>6</sup> to 10<sup>0</sup> copies per reaction. The limit of detection (LOD, where 95% of technical replicates amplify) is marked with a solid red line and the limit of quantification (LOQ, the lowest initial DNA concentration quantifiable with a coefficient of variation below 35%) is marked with a dashed line. (DOCX)

Publication Details

Journal
Figshare
Published
2025-02-04
DOI
https://doi.org/10.1371/journal.pone.0318414.s007
Primary Topic
Liver physiology and pathology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assay validation with temperature gradient and standard curve.

Figshare
Liver physiology and pathology
article

Assay validation with temperature gradient and standard curve.

article en

Abstract

Assay development consisted of a temperature gradient approach on standard samples of DNA extracted from <i>Chondria tumulosa</i> tissue and no-template controls (NTC) to monitor for contamination. (a) The ideal annealing temperature (54.7–64°C) was selected among triplicate amplifications that produced a sigmoidal curve in the fewest cycles. (b) Melt curves were verified to only produce a single tall, narrow peak. (c) Threshold cycle (C<sub>q</sub>) values are plotted against triplicate DNA serial dilution starting concentrations to generate a best fit standard curve (R<sup>2</sup> = 0.999, slope = -3.79, intercept = 33.62), using the curve-fitting approach [<a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0318414#pone.0318414.ref063" target="_blank">63</a>]. Synthetic <i>C</i>. <i>tumulosa</i> DNA was quantified using a fluorometer (Qubit, Invitrogen) and diluted to create 10-fold serial dilutions ranging from 10<sup>6</sup> to 10<sup>0</sup> copies per reaction. The limit of detection (LOD, where 95% of technical replicates amplify) is marked with a solid red line and the limit of quantification (LOQ, the lowest initial DNA concentration quantifiable with a coefficient of variation below 35%) is marked with a dashed line. (DOCX)

Figshare
Openalex Percentile: Top 43%
Liver physiology and pathology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.