Application of sacral-2-alar screws in lumbosacral stability

Objective To explore the maximum pull-out force of alar screws fixation in sacral 2 and investigate the effectiveness of this internal fixation method. Methods Five adult cadaver specimens fixed and wetted with formaldehyde solution were selected, as well as six fresh frozen cadavers. Randomly place three types of sacral screws on both sides of the same cadaver specimen, including: sacral-2-alar screws reinforced with bone cement (S2 group), S1 pedicle screw (S1 group), sacral-2-alar-iliac screws (S2AI group). The instantaneous maximum pull-out force values of three groups of sacral screws by applying axial pull-out force to the screws were recorded. Results The maximum axial pullout force of screws in 11 cadaver specimens was (521.80 ± 98.98)N in S2 group, (843.16±107.64)N in S1 group, and (536.04±145.78)N in S2AI group, and the difference among three groups was significant (F=25.52, P<0.01). The strength of S2 group and S2AI group was comparable, and there was no significant difference between the two groups (P>0.05). Conclusion Sacral-2-alar screws reinforced with bone cement have good mechanical properties and are suitable for clinical application.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.13429/j.cnki.cjcr.2025.04.040
Primary Topic
Pelvic and Acetabular Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of sacral-2-alar screws in lumbosacral stability

SHILAP Revista de lepidopterología
Pelvic and Acetabular Injuries
article

Application of sacral-2-alar screws in lumbosacral stability

article en

Abstract

Objective To explore the maximum pull-out force of alar screws fixation in sacral 2 and investigate the effectiveness of this internal fixation method. Methods Five adult cadaver specimens fixed and wetted with formaldehyde solution were selected, as well as six fresh frozen cadavers. Randomly place three types of sacral screws on both sides of the same cadaver specimen, including: sacral-2-alar screws reinforced with bone cement (S2 group), S1 pedicle screw (S1 group), sacral-2-alar-iliac screws (S2AI group). The instantaneous maximum pull-out force values of three groups of sacral screws by applying axial pull-out force to the screws were recorded. Results The maximum axial pullout force of screws in 11 cadaver specimens was (521.80 ± 98.98)N in S2 group, (843.16±107.64)N in S1 group, and (536.04±145.78)N in S2AI group, and the difference among three groups was significant (F=25.52, P<0.01). The strength of S2 group and S2AI group was comparable, and there was no significant difference between the two groups (P>0.05). Conclusion Sacral-2-alar screws reinforced with bone cement have good mechanical properties and are suitable for clinical application.

SHILAP Revista de lepidopterología
Loudi Central Hospital (CN), University of South China (CN)
Openalex Percentile: Top 37%
Pelvic and Acetabular Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.