Experimental research and application of high pressure spray cooling in long distance coal mining face

For the problem of high temperature heat damage at 1012102 working face in Yuanzigou Mine, the best spray pressure and nozzle atomization parameters are determined by using the method of spray cooling experiment. The numerical simulation method is used to simulate and analyze the influence of different spray temperature and spray spacing conditions on the cooling effect, and the comfort of human body before and after spray is used to analyze by the linear regression method. The results show that: when the spraying system in the synthesized mining face adopts the group spacing of 10 m, the water temperature is 286 K, and the pressure is 6 MPa, the single group peak temperature reaches 1.3 ℃ compared with the conventional ventilation method. After the application in the field, the temperature of most areas on the sidewalk side of the working face was lower than 26 ℃, the maximum temperature dropped to below 27 ℃, the minimum temperature was as low as 24.7 ℃, which effectively realized the regional cool.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.13347/j.cnki.mkaq.20231466
Primary Topic
Education Methods and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental research and application of high pressure spray cooling in long distance coal mining face

SHILAP Revista de lepidopterología
Education Methods and Technologies
article

Experimental research and application of high pressure spray cooling in long distance coal mining face

article en

Abstract

For the problem of high temperature heat damage at 1012102 working face in Yuanzigou Mine, the best spray pressure and nozzle atomization parameters are determined by using the method of spray cooling experiment. The numerical simulation method is used to simulate and analyze the influence of different spray temperature and spray spacing conditions on the cooling effect, and the comfort of human body before and after spray is used to analyze by the linear regression method. The results show that: when the spraying system in the synthesized mining face adopts the group spacing of 10 m, the water temperature is 286 K, and the pressure is 6 MPa, the single group peak temperature reaches 1.3 ℃ compared with the conventional ventilation method. After the application in the field, the temperature of most areas on the sidewalk side of the working face was lower than 26 ℃, the maximum temperature dropped to below 27 ℃, the minimum temperature was as low as 24.7 ℃, which effectively realized the regional cool.

SHILAP Revista de lepidopterología
Openalex Percentile: Top 39%
Education Methods and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.