Study on simultaneous determination of arsenic speciation and selenium speciation in selenium-rich foods by HPLC-ICP-MS

[Objective] A method for the simultaneous determination of arsenate [As(Ⅲ)], Arsenate [As(Ⅴ)], monomethylarsenate (MMA), dimethylarsenate (DMA), Arsine betaine (AsB), methyl-selenocysteine (MeSeCys) and selenomide in food was developed by high performance liquid phase inductively coupled plasma mass spectrometry (HPLC-ICP-MS), and a total of 10 kinds of arsenic and selenium element forms of As and Se, including acid (SeMet), selenocysteine (SeCys2), selenite [Se(Ⅳ)] and selenate [Se(Ⅵ)] . [Methods] Taking selenium rich rice as the research object, the best extraction method was determined by comparing different extraction methods and different kinds of enzymes. Moreover, different chromatographic columns, mobile phase composition, mobile phase pH, mobile phase flow, mobile phase methanol content and column temperature were compared to determine the best extraction and separation conditions. [Results] The optimal separation conditions were using Aglient ZORBAX SB-Aq chromatographic column with 20 mmol/L citric acid + 5 mmol/L sodium hexane sulfonate + 4% methanol as the mobile phase gradient with pH values of 4.0 and 6.0 respectively. Elution was performed at a flow rate of 1.0 mL/min, and inductively coupled plasma mass spectrometry (ICP-MS) was detected using HEHe mode. The optimal extraction condition is Tris-HCl (pH 7.5) buffer solution adding 15 mg proteinase K and 15 mg proteinase E. This method can completely separate 10 different forms of arsenic and selenium within 5 minutes. In the range of 0~50 μg/L, the linear relationship between the forms of each element is good, and the correlation coefficient <i>R</i>>0.999 5. The detection limits of As(Ⅴ), MMA, As(Ⅲ), DMA, AsB, Se(Ⅵ), Se(Ⅳ), SeCys2, MeSeCys and SeMet are 0.10, 0.10, 0.12, 0.14, 0.22, 0.15, 0.15, 0.18, 0.12, 0.15 μg/L respectively. The spiked recovery rate ranged from 76.0% to 104.2%, and the relative standard deviation ranged from 1.1% to 8.5%. [Conclusion] This method is simple, fast, highly sensitive and fully meets the requirements for accurate quantitative analysis of arsenic and selenium speciation in selenium-rich foods.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.13652/j.spjx.1003.5788.2023.81287
Primary Topic
Arsenic contamination and mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on simultaneous determination of arsenic speciation and selenium speciation in selenium-rich foods by HPLC-ICP-MS

SHILAP Revista de lepidopterología
Arsenic contamination and mitigation
article

Study on simultaneous determination of arsenic speciation and selenium speciation in selenium-rich foods by HPLC-ICP-MS

article en

Abstract

[Objective] A method for the simultaneous determination of arsenate [As(Ⅲ)], Arsenate [As(Ⅴ)], monomethylarsenate (MMA), dimethylarsenate (DMA), Arsine betaine (AsB), methyl-selenocysteine (MeSeCys) and selenomide in food was developed by high performance liquid phase inductively coupled plasma mass spectrometry (HPLC-ICP-MS), and a total of 10 kinds of arsenic and selenium element forms of As and Se, including acid (SeMet), selenocysteine (SeCys2), selenite [Se(Ⅳ)] and selenate [Se(Ⅵ)] . [Methods] Taking selenium rich rice as the research object, the best extraction method was determined by comparing different extraction methods and different kinds of enzymes. Moreover, different chromatographic columns, mobile phase composition, mobile phase pH, mobile phase flow, mobile phase methanol content and column temperature were compared to determine the best extraction and separation conditions. [Results] The optimal separation conditions were using Aglient ZORBAX SB-Aq chromatographic column with 20 mmol/L citric acid + 5 mmol/L sodium hexane sulfonate + 4% methanol as the mobile phase gradient with pH values of 4.0 and 6.0 respectively. Elution was performed at a flow rate of 1.0 mL/min, and inductively coupled plasma mass spectrometry (ICP-MS) was detected using HEHe mode. The optimal extraction condition is Tris-HCl (pH 7.5) buffer solution adding 15 mg proteinase K and 15 mg proteinase E. This method can completely separate 10 different forms of arsenic and selenium within 5 minutes. In the range of 0~50 μg/L, the linear relationship between the forms of each element is good, and the correlation coefficient <i>R</i>>0.999 5. The detection limits of As(Ⅴ), MMA, As(Ⅲ), DMA, AsB, Se(Ⅵ), Se(Ⅳ), SeCys2, MeSeCys and SeMet are 0.10, 0.10, 0.12, 0.14, 0.22, 0.15, 0.15, 0.18, 0.12, 0.15 μg/L respectively. The spiked recovery rate ranged from 76.0% to 104.2%, and the relative standard deviation ranged from 1.1% to 8.5%. [Conclusion] This method is simple, fast, highly sensitive and fully meets the requirements for accurate quantitative analysis of arsenic and selenium speciation in selenium-rich foods.

SHILAP Revista de lepidopterología
Zero hunger
Openalex Percentile: Top 69%
Arsenic contamination and mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.