Research on hand-eye calibration method of robot grasping system based on visual guidance

[Objective] Designing a apace grid-based hand-eye calibration method to reduce robot positioning errors and calibration object Recognition errors in automated food production lines. [Methods] Based on the composition of the attitude matrix, the attitude and position of the end of the robot relative to the camera were obtained by translating and rotating the end of the robot, and a registration method using known corresponding point pairs was proposed to reduce the influence of the robot positioning error on the attitude solution in the translation method. Based on the space circle fitting method, a two-point vector method was proposed to solve the end position, which reduced the amount of data collection. A method of fitting the center of the sphere was proposed to compensate for the result of hand-eye calibration. [Results] The average measured error after calibration is 0.8 mm. [Conclusion] The hand-eye system based on the Eye-In-Hand type, can realize high-precision object positioning.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-09-01
DOI
https://doi.org/10.13652/j.spjx.1003.5788.2023.80944
Citations
1
Primary Topic
Robotic Mechanisms and Dynamics
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on hand-eye calibration method of robot grasping system based on visual guidance

1 citations
SHILAP Revista de lepidopterología
Robotic Mechanisms and Dynamics
0.33
article

Research on hand-eye calibration method of robot grasping system based on visual guidance

article en
1 citations

Abstract

[Objective] Designing a apace grid-based hand-eye calibration method to reduce robot positioning errors and calibration object Recognition errors in automated food production lines. [Methods] Based on the composition of the attitude matrix, the attitude and position of the end of the robot relative to the camera were obtained by translating and rotating the end of the robot, and a registration method using known corresponding point pairs was proposed to reduce the influence of the robot positioning error on the attitude solution in the translation method. Based on the space circle fitting method, a two-point vector method was proposed to solve the end position, which reduced the amount of data collection. A method of fitting the center of the sphere was proposed to compensate for the result of hand-eye calibration. [Results] The average measured error after calibration is 0.8 mm. [Conclusion] The hand-eye system based on the Eye-In-Hand type, can realize high-precision object positioning.

SHILAP Revista de lepidopterología
Zero hunger
Openalex Percentile: Top 35%
Robotic Mechanisms and Dynamics
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.