A Fault Diagnosis Method for Interturn Short Circuit of Dry-Type Air-Core Reactor Based on High Frequency Impedance Spectrum

A detection method for interturn short circuit fault in dry-type air-core reactor is proposed using broadband impedance spectroscopy. Firstly, an equivalent distributed circuit model of intact reactor under high frequency is constructed based on the theory of multi-conductor transmission lines, and an equivalent simulation model is established based on the parameter calculation equation of the distributed equivalent circuit to analyze the high-frequency characteristics of the reactor broadband impedance spectrum. Secondly, the amplitude spectrum and phase spectrum of the broadband impedance of the reactor with interturn short circuit fault are simulated to analyze the influence of inductance parameters on the resonant frequency of the reactor impedance spectrum. Finally, an experimental testing was conducted on a small dry-type air-core reactor in the laboratory, which has verified the effectiveness of the proposed method.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.11930/j.issn.1004-9649.202309025
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fault Diagnosis Method for Interturn Short Circuit of Dry-Type Air-Core Reactor Based on High Frequency Impedance Spectrum

SHILAP Revista de lepidopterología
High-Voltage Power Transmission Systems
article

A Fault Diagnosis Method for Interturn Short Circuit of Dry-Type Air-Core Reactor Based on High Frequency Impedance Spectrum

article en

Abstract

A detection method for interturn short circuit fault in dry-type air-core reactor is proposed using broadband impedance spectroscopy. Firstly, an equivalent distributed circuit model of intact reactor under high frequency is constructed based on the theory of multi-conductor transmission lines, and an equivalent simulation model is established based on the parameter calculation equation of the distributed equivalent circuit to analyze the high-frequency characteristics of the reactor broadband impedance spectrum. Secondly, the amplitude spectrum and phase spectrum of the broadband impedance of the reactor with interturn short circuit fault are simulated to analyze the influence of inductance parameters on the resonant frequency of the reactor impedance spectrum. Finally, an experimental testing was conducted on a small dry-type air-core reactor in the laboratory, which has verified the effectiveness of the proposed method.

SHILAP Revista de lepidopterología
Harbin University of Science and Technology (CN), Harbin Electric Corporation (China) (CN)
Openalex Percentile: Top 67%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.