Exposed conductor detection of 10 kV distribution line based on improved YOLOv8

Exposed conductors in 10 kV distribution line are one of the major causes with operational faults in distribution lines, continuously affecting the safe and stable operation of the distribution network. Traditional manual inspection methods often fail to detect such defects in a timely manner. A detection method for exposed conductors in 10 kV distribution lines is proposd based on an improved YOLOv8 algorithm,which is designed to assist power grid maintenance personnel detecting conductor exposed defects quickly and efficiently. The algorithm replaces the original convolution with omni-dimensional dynamic convolution in the backbone network, enhancing the features of exposed conductors through multi-dimensional feature extraction. In the neck network, the connection between high-level and low-level features is enhanced by combining attention embedding module with the cross stage feature fusion module of the original network, thereby analyzing both the overall shape and local details of exposed conductors. For the loss function, distance intersection over union with normalized wasserstein distance is combined to increase focus on cases where targets are small or background interference exists in drone inspection photographs. The experimental results demonstrate that the improved algorithm achieves increases of 4.8 percentage points, 4.2 percentage points, and 5.2 percentage points in precision, recall, and mean average precision, respectively, compared to the original algorithm. This effectively enhances the detection capability for exposed distribution conductors, providing a new technical approach for ensuring the safe and stable operation of power systems.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.12158/j.2096-3203.2025.03.019
Primary Topic
Power Line Inspection Robots
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exposed conductor detection of 10 kV distribution line based on improved YOLOv8

SHILAP Revista de lepidopterología
Power Line Inspection Robots
article

Exposed conductor detection of 10 kV distribution line based on improved YOLOv8

article en

Abstract

Exposed conductors in 10 kV distribution line are one of the major causes with operational faults in distribution lines, continuously affecting the safe and stable operation of the distribution network. Traditional manual inspection methods often fail to detect such defects in a timely manner. A detection method for exposed conductors in 10 kV distribution lines is proposd based on an improved YOLOv8 algorithm,which is designed to assist power grid maintenance personnel detecting conductor exposed defects quickly and efficiently. The algorithm replaces the original convolution with omni-dimensional dynamic convolution in the backbone network, enhancing the features of exposed conductors through multi-dimensional feature extraction. In the neck network, the connection between high-level and low-level features is enhanced by combining attention embedding module with the cross stage feature fusion module of the original network, thereby analyzing both the overall shape and local details of exposed conductors. For the loss function, distance intersection over union with normalized wasserstein distance is combined to increase focus on cases where targets are small or background interference exists in drone inspection photographs. The experimental results demonstrate that the improved algorithm achieves increases of 4.8 percentage points, 4.2 percentage points, and 5.2 percentage points in precision, recall, and mean average precision, respectively, compared to the original algorithm. This effectively enhances the detection capability for exposed distribution conductors, providing a new technical approach for ensuring the safe and stable operation of power systems.

SHILAP Revista de lepidopterología
Nanjing Institute of Technology (CN)
Openalex Percentile: Top 55%
Power Line Inspection Robots
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.