Safety assessment of electromagnetic exposure from a 13.56 MHz RF anti-theft device

Radio frequency anti-theft devices employ radio frequency identification (RFID) technology to identify and track objects. An anti-theft system based on the identification of information legitimacy judgment realizes an anti-theft alarm function. In this study, we effectively evaluated the safety of a 13.56 MHz RF anti-theft device in terms of electromagnetic exposure of pedestrians using the RF module in the COMSOL Multiphysics software. To this end, we designed an electromagnetic environment model to study the public electromagnetic exposure of pedestrians when such an RF anti-theft device is used. In particular, four exposure scenarios were analyzed in which the antenna system of the RF antitheft device was operating at 100 mW and 1 W and a pedestrian was located at the center (location A) and 25 cm away in front of the center (location B) of the anti-theft device. The results showed that when the pedestrian was at location A, for the aforementioned antenna feed power of 100 mW and 1 W, the maximum electric field strength of the whole body tissue was 0.26 V/m and 0.84 V/m, and the maximum magnetic field strength was 0.05 A/m and 0.16 A/m, respectively. The maximum values of the specific absorption rate (SAR) were 1.55×10-5 W/kg and 1.5×10-4 W/kg, respectively. When the pedestrian was at location B, for the aforementioned antenna feeding power of 100 mW and 1 W, the maximum electric field strength of the whole body tissue was 0.1 V/m and 0.36 V/m, and the maximum magnetic field strength was 2.08×10-3 A/m and 6.56×10-3 A/m, respectively. In this case, the maximum SAR values were 2.29×10-6 W/kg and 2.92×10-5 W/kg, respectively. These values obtained from simulation are lower than the public electromagnetic exposure limit established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). This indicates that pedestrians passing through the RF electromagnetic environment analyzed in this study are within a safe range of public electromagnetic exposure. Therefore, the proposed anti-theft device does not pose a threat to public health.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.11889/j.1000-3436.2024-0025
Primary Topic
Medical History and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety assessment of electromagnetic exposure from a 13.56 MHz RF anti-theft device

SHILAP Revista de lepidopterología
Medical History and Research
article

Safety assessment of electromagnetic exposure from a 13.56 MHz RF anti-theft device

article en

Abstract

Radio frequency anti-theft devices employ radio frequency identification (RFID) technology to identify and track objects. An anti-theft system based on the identification of information legitimacy judgment realizes an anti-theft alarm function. In this study, we effectively evaluated the safety of a 13.56 MHz RF anti-theft device in terms of electromagnetic exposure of pedestrians using the RF module in the COMSOL Multiphysics software. To this end, we designed an electromagnetic environment model to study the public electromagnetic exposure of pedestrians when such an RF anti-theft device is used. In particular, four exposure scenarios were analyzed in which the antenna system of the RF antitheft device was operating at 100 mW and 1 W and a pedestrian was located at the center (location A) and 25 cm away in front of the center (location B) of the anti-theft device. The results showed that when the pedestrian was at location A, for the aforementioned antenna feed power of 100 mW and 1 W, the maximum electric field strength of the whole body tissue was 0.26 V/m and 0.84 V/m, and the maximum magnetic field strength was 0.05 A/m and 0.16 A/m, respectively. The maximum values of the specific absorption rate (SAR) were 1.55×10-5 W/kg and 1.5×10-4 W/kg, respectively. When the pedestrian was at location B, for the aforementioned antenna feeding power of 100 mW and 1 W, the maximum electric field strength of the whole body tissue was 0.1 V/m and 0.36 V/m, and the maximum magnetic field strength was 2.08×10-3 A/m and 6.56×10-3 A/m, respectively. In this case, the maximum SAR values were 2.29×10-6 W/kg and 2.92×10-5 W/kg, respectively. These values obtained from simulation are lower than the public electromagnetic exposure limit established by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). This indicates that pedestrians passing through the RF electromagnetic environment analyzed in this study are within a safe range of public electromagnetic exposure. Therefore, the proposed anti-theft device does not pose a threat to public health.

SHILAP Revista de lepidopterología
Lanzhou Jiaotong University (CN)
Openalex Percentile: Top 46%
Medical History and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Safety assessment of electromagnetic exposure from a 13.56 MHz RF anti-theft device · SHILAP Revista de lepidopterología (2024) | TGRS Research Map | TGRS