Design of bunch length and charge monitor based on cavity resonator for injector of Super Tau-Charm Facility

BackgroundThe Super Tau Charm Facility (STCF) is a new generation electron-positron colliders at the forefront of high precision, and its high brightness requirements pose a major challenge to accelerator technology. Resonant cavity-based monitors utilize characteristic mode signals for non-intercepting, high signal-to-noise ratio measurements, hence may meet the online high-resolution measurement requirements of various high-quality linear accelerators.PurposeThis study aims to address the challenges posed by the short lifetime and the small dynamic aperture of the storage ring beams in the STCF by developing high-resolution monitoring techniques for bunch length and charge to ensure efficient injection and precise measurement of these parameters.MethodsAccording to the beam parameters and measurement requirements of the STCF injector, the physical design and simulation of the resonator bunch length and charge monitor were carried out. Two Pill-Box cavities were designed by using Computer Simulation Technology (CST) modeling, and their structures were optimized. Subsequently, the beam load in the CST particle studio for simulation was conducted to analyze influences of beam tilt and lateral offset on the measurement accuracy, and the measuring resolutions of bunch length and charge were evaluated using cavity beam position monitor (CBPM).ResultsSimulation results show that the measurement errors of bunch length and charge are 3.3% and 0.02%, respectively. According to the online test results of the same type monitor, it is estimated that the resolution of bunch length of the monitor is expected to reach 100 [email protected] nC, and the relative resolution of charge measurement is better than 0.07%.ConclusionsThe currently designed monitor meets the diagnostic requirements of bunch length and charge of STCF, it will be manufactured in future for online testing.

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-10-01
DOI
https://doi.org/10.11889/j.0253-3219.2024.hjs.47.100204
Citations
2
Primary Topic
Sociology and Education Studies
Type
article
Field-Weighted Citation Impact
2.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of bunch length and charge monitor based on cavity resonator for injector of Super Tau-Charm Facility

2 citations
SHILAP Revista de lepidopterología
Sociology and Education Studies
2.26
article

Design of bunch length and charge monitor based on cavity resonator for injector of Super Tau-Charm Facility

article en
2 citations

Abstract

BackgroundThe Super Tau Charm Facility (STCF) is a new generation electron-positron colliders at the forefront of high precision, and its high brightness requirements pose a major challenge to accelerator technology. Resonant cavity-based monitors utilize characteristic mode signals for non-intercepting, high signal-to-noise ratio measurements, hence may meet the online high-resolution measurement requirements of various high-quality linear accelerators.PurposeThis study aims to address the challenges posed by the short lifetime and the small dynamic aperture of the storage ring beams in the STCF by developing high-resolution monitoring techniques for bunch length and charge to ensure efficient injection and precise measurement of these parameters.MethodsAccording to the beam parameters and measurement requirements of the STCF injector, the physical design and simulation of the resonator bunch length and charge monitor were carried out. Two Pill-Box cavities were designed by using Computer Simulation Technology (CST) modeling, and their structures were optimized. Subsequently, the beam load in the CST particle studio for simulation was conducted to analyze influences of beam tilt and lateral offset on the measurement accuracy, and the measuring resolutions of bunch length and charge were evaluated using cavity beam position monitor (CBPM).ResultsSimulation results show that the measurement errors of bunch length and charge are 3.3% and 0.02%, respectively. According to the online test results of the same type monitor, it is estimated that the resolution of bunch length of the monitor is expected to reach 100 [email protected] nC, and the relative resolution of charge measurement is better than 0.07%.ConclusionsThe currently designed monitor meets the diagnostic requirements of bunch length and charge of STCF, it will be manufactured in future for online testing.

SHILAP Revista de lepidopterología
Industry, innovation and infrastructure
Openalex Percentile: Top 9%
Sociology and Education Studies
2.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.