Simultaneous determination of 22 volatile organic compounds in urine of automotive spray painting workers using static headspace gas chromatography-mass spectrometry

BackgroundAutomotive repair workers are exposed to a wide variety of volatile organic compounds (VOCs) during painting operations, which poses significant health risks. Biomonitoring can directly reflect the internal body burden of these compounds. Therefore, it is essential to develop an analytical method for simultaneous determination of VOCs in the urine of automotive spray painting workers. ObjectiveTo establish a static headspace gas chromatography-mass spectrometry (GC-MS) method for simultaneously determining 22 VOCs in the urine of spray painting workers in automotive repair enterprises. MethodsAn automatic headspace sampler was used for the pretreatment of urine samples. The headspace conditions as well as the chromatographic and mass spectrometric conditions of static headspace GC-MS were optimized. The separation of 22 VOCs was achieved by optimizing the temperature program. Sensitivity was enhanced by optimizing the quantitative ions. The signal response of VOCs was improved by optimizing the headspace equilibrium temperature, equilibrium time, and the amount of inorganic salt added. The method's detection limit, lower limit of quantification, accuracy, precision, and stability were tested using blank urine samples spiked with standards. Additionally, the method was applied to examine 40 urine samples collected from painting workers in automotive repair enterprises in Tianjin. ResultsIn this study, the headspace equilibrium temperature was set at 80 ℃, the equilibrium time was 30 min, and the salt addition amount was 2.0 g. A DB-624ms chromatographic column was selected for the separation of 22 VOCs. The initial temperature of heating program was 50 ℃, maintained for 15 min, and then increased to 85 ℃ at a heating rate of 10 ℃·min−1 for 10 min, followed by increasing to 90 ℃ at a heating rate of 5 ℃·min−1 for 20 min. The single ion monitoring (SIM) mode was chosen for the quantitative analysis of the 22 VOCs. The method demonstrated good linearity for determining 22 target analytes in the urine of spray painting workers, with correlation coefficients all above 0.990. The lower limits of quantification (LOQ) for the components ranged from 0.4 to 3.8 μg·L−1. The spiked recovery rates of the samples were between 80.1% and 112.1%, and the relative standard deviations (RSD) ranged from 1.5% to 9.7%. All target analytes could be stored at 4 ℃ for 5 d and at −20 ℃ for 7 d. This method was applied to evaluate urine samples from 40 spray painting workers in automotive repair enterprises in Tianjin. The positive rate of butyl acetate was 37.5%. The positive rate of xylene was 32.5%. The positive rate of toluene was 30.0%. The positive rate of isopropanol was 25.0%. The concentration range of the detected substances was from <lower limit of quantification to 60.56 µg·L−1. ConclusionThe established simultaneous determination protocol of 22 VOCs by static headspace- GC-MS is characterized by its simplicity, high sensitivity, excellent selectivity, and high accuracy. It is suitable for urine samples of spray painting workers in automotive repair industry.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.11836/jeom24421
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous determination of 22 volatile organic compounds in urine of automotive spray painting workers using static headspace gas chromatography-mass spectrometry

SHILAP Revista de lepidopterología
Advanced Chemical Sensor Technologies
article

Simultaneous determination of 22 volatile organic compounds in urine of automotive spray painting workers using static headspace gas chromatography-mass spectrometry

article en

Abstract

BackgroundAutomotive repair workers are exposed to a wide variety of volatile organic compounds (VOCs) during painting operations, which poses significant health risks. Biomonitoring can directly reflect the internal body burden of these compounds. Therefore, it is essential to develop an analytical method for simultaneous determination of VOCs in the urine of automotive spray painting workers. ObjectiveTo establish a static headspace gas chromatography-mass spectrometry (GC-MS) method for simultaneously determining 22 VOCs in the urine of spray painting workers in automotive repair enterprises. MethodsAn automatic headspace sampler was used for the pretreatment of urine samples. The headspace conditions as well as the chromatographic and mass spectrometric conditions of static headspace GC-MS were optimized. The separation of 22 VOCs was achieved by optimizing the temperature program. Sensitivity was enhanced by optimizing the quantitative ions. The signal response of VOCs was improved by optimizing the headspace equilibrium temperature, equilibrium time, and the amount of inorganic salt added. The method's detection limit, lower limit of quantification, accuracy, precision, and stability were tested using blank urine samples spiked with standards. Additionally, the method was applied to examine 40 urine samples collected from painting workers in automotive repair enterprises in Tianjin. ResultsIn this study, the headspace equilibrium temperature was set at 80 ℃, the equilibrium time was 30 min, and the salt addition amount was 2.0 g. A DB-624ms chromatographic column was selected for the separation of 22 VOCs. The initial temperature of heating program was 50 ℃, maintained for 15 min, and then increased to 85 ℃ at a heating rate of 10 ℃·min−1 for 10 min, followed by increasing to 90 ℃ at a heating rate of 5 ℃·min−1 for 20 min. The single ion monitoring (SIM) mode was chosen for the quantitative analysis of the 22 VOCs. The method demonstrated good linearity for determining 22 target analytes in the urine of spray painting workers, with correlation coefficients all above 0.990. The lower limits of quantification (LOQ) for the components ranged from 0.4 to 3.8 μg·L−1. The spiked recovery rates of the samples were between 80.1% and 112.1%, and the relative standard deviations (RSD) ranged from 1.5% to 9.7%. All target analytes could be stored at 4 ℃ for 5 d and at −20 ℃ for 7 d. This method was applied to evaluate urine samples from 40 spray painting workers in automotive repair enterprises in Tianjin. The positive rate of butyl acetate was 37.5%. The positive rate of xylene was 32.5%. The positive rate of toluene was 30.0%. The positive rate of isopropanol was 25.0%. The concentration range of the detected substances was from <lower limit of quantification to 60.56 µg·L−1. ConclusionThe established simultaneous determination protocol of 22 VOCs by static headspace- GC-MS is characterized by its simplicity, high sensitivity, excellent selectivity, and high accuracy. It is suitable for urine samples of spray painting workers in automotive repair industry.

SHILAP Revista de lepidopterología
Tianjin Centers for Disease Control and Prevention (CN)
Openalex Percentile: Top 56%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.