Laser Fabrication\nof Humidity Sensors on Ethanol-Soaked\nPolyimide for Fully Contactless Respiratory Monitoring

Humidity-sensor-based fully contactless respiratory monitoring\ncan eliminate the discomfort and infection risks associated with any\nwearable device. However, challenges in the facile fabrication of\nhighly sensitive humidity sensors continue to hinder their widespread\napplication for fully contactless respiratory monitoring. In this\nstudy, we introduce a simple method to fabricate highly sensitive\nhumidity sensors. Our method employs laser-induced graphene (LIG)\non an ethanol-soaked polyimide (PI) film as the electrode of the humidity\nsensor. The ethanol-soaked PI between adjacent LIG electrodes functions\nas the sensing material, enabling ion-conductive humidity sensing.\nCompared to the LIG humidity sensors fabricated on untreated PI films,\nLIG humidity sensors fabricated on ethanol-soaked PI films exhibit\nsuperior performance with higher linearity (<i>R</i><sup>2</sup> = 0.9936), reduced hysteresis (Δ<i>H</i> =\n5.1% RH), and increased sensitivity (0.65%/RH). Notably, the LIG humidity\nsensor fabricated on the ethanol-soaked PI film can detect a person’s\nbreathing from a distance of 30 cm, a capability not achieved by sensors\nfabricated on untreated PI films. Moreover, incorporating these LIG\nhumidity sensors into an array further enhances both the detection\ndistance and the sensitivity for respiratory monitoring. Experimental\nresults demonstrate that the LIG humidity sensor array can be employed\nfor fully contactless on-bed respiration monitoring and for continuous,\nfully contactless monitoring of the respiratory rate during treadmill\nexercise. These results highlight the great potential of our LIG humidity\nsensors for various practical applications in medicine and sports.

Publication Details

Journal
Figshare
Published
2024-08-14
DOI
https://doi.org/10.1021/acsami.4c07731.s001
Primary Topic
Educational Robotics and Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laser Fabrication\nof Humidity Sensors on Ethanol-Soaked\nPolyimide for Fully Contactless Respiratory Monitoring

Figshare
Educational Robotics and Engineering
article

Laser Fabrication\nof Humidity Sensors on Ethanol-Soaked\nPolyimide for Fully Contactless Respiratory Monitoring

article en

Abstract

Humidity-sensor-based fully contactless respiratory monitoring\ncan eliminate the discomfort and infection risks associated with any\nwearable device. However, challenges in the facile fabrication of\nhighly sensitive humidity sensors continue to hinder their widespread\napplication for fully contactless respiratory monitoring. In this\nstudy, we introduce a simple method to fabricate highly sensitive\nhumidity sensors. Our method employs laser-induced graphene (LIG)\non an ethanol-soaked polyimide (PI) film as the electrode of the humidity\nsensor. The ethanol-soaked PI between adjacent LIG electrodes functions\nas the sensing material, enabling ion-conductive humidity sensing.\nCompared to the LIG humidity sensors fabricated on untreated PI films,\nLIG humidity sensors fabricated on ethanol-soaked PI films exhibit\nsuperior performance with higher linearity (<i>R</i><sup>2</sup> = 0.9936), reduced hysteresis (Δ<i>H</i> =\n5.1% RH), and increased sensitivity (0.65%/RH). Notably, the LIG humidity\nsensor fabricated on the ethanol-soaked PI film can detect a person’s\nbreathing from a distance of 30 cm, a capability not achieved by sensors\nfabricated on untreated PI films. Moreover, incorporating these LIG\nhumidity sensors into an array further enhances both the detection\ndistance and the sensitivity for respiratory monitoring. Experimental\nresults demonstrate that the LIG humidity sensor array can be employed\nfor fully contactless on-bed respiration monitoring and for continuous,\nfully contactless monitoring of the respiratory rate during treadmill\nexercise. These results highlight the great potential of our LIG humidity\nsensors for various practical applications in medicine and sports.

Figshare
Openalex Percentile: Top 64%
Educational Robotics and Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laser Fabrication\nof Humidity Sensors on Ethanol-Soaked\nPolyimide for Fully Contactless Respiratory Monitoring · Figshare (2024) | TGRS Research Map | TGRS