Simulation analysis of work posture and muscle fatigue in breaking and connecting contact terminal

BackgroundWhen live working line operators engage in upper limb operations, working for a long time with raising arms and the exposure to adverse ergonomic factors tend to increase muscle load, cause fatigue accumulation, and increase the risk of work-related musculoskeletal disorders (WMSDs). ObjectiveTo analyze work posture and associated muscle fatigue during executing breaking/connecting contact terminal, and identify adverse ergonomic factors of the work process. MethodsThis study recruited 10 volunteers to perform breaking/connecting contact terminal simulation. At a distance of 4.5, 3.5, and 2.5 m from the body to the wire, each performed the task 5 times. Visual 3D was used to analyze the kinematic data from motion capture. The surface electromyography (sEMG) signals of the deltoid, biceps, triceps, and brachioradialis were recorded during the simulation and analyzed for muscle fatigue using root mean square (RMS), median frequency (MF), and jointed EMG amplitude and spectrum analysis (JASA). After completion of each task, Borg scale was used to query the volunteers of their subjective fatigue. A 2-min rest was required between each distance. ResultsThe kinematic data from motion capture showed that in the entire process of the task, the right upper limb was higher when lifting, with the right shoulder joint maintaining flexion and fluctuating periodically between abduction and adduction, external and internal rotation, the right elbow joint maintaining flexion and supination. The frequency of task cycle showed a significant effect on the Borg scale scores (P<0.001, partial \begin{document}$ {\eta }^{2} $\end{document}=0.464); the distance showed no significant effect on the Borg scale scores (P>0.05, partial \begin{document}$ {\eta }^{2} $\end{document}=0.002); their interaction effect was not significant (P>0.05, partial \begin{document}$ {\eta }^{2} $\end{document}=0.020). The results of the sEMG signals showed that at a distance of 4.5 m, the volunteers had the highest percentages of maximal voluntary electrical activation (MVE%) in the deltoid and right brachioradialis and the lowest MF values in the deltoid and left brachioradialis after completing 5 task cycles. The results of JASA showed that fatigue was observed in brachioradialis and deltoid after completing 5 task cycles at a distance of 4.5 m, the right deltoid and right brachioradialis at a distance of 3.5 m, in the brachioradialis, deltoid, and left bicep at a distance of 2.5 m. ConclusionThe subjective fatigue of workers who engaged in breaking/connecting contact terminal elevates with more repetitive operations. Based on the sEMG and motion capture analysis, it can be found that improper distance between the workers and the target work area can increase the burden from poor posture and improper use of work equipment, and lead to muscle fatigue; the deltoid and brachioradialis are the key muscles of fatigue in this type of operation; changing the angle of the elbow joint and the shoulder joint during the process of the operation can affect the deltoid and brachioradialis exertion and loading.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.11836/jeom24384
Primary Topic
Musculoskeletal pain and rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation analysis of work posture and muscle fatigue in breaking and connecting contact terminal

SHILAP Revista de lepidopterología
Musculoskeletal pain and rehabilitation
article

Simulation analysis of work posture and muscle fatigue in breaking and connecting contact terminal

article en

Abstract

BackgroundWhen live working line operators engage in upper limb operations, working for a long time with raising arms and the exposure to adverse ergonomic factors tend to increase muscle load, cause fatigue accumulation, and increase the risk of work-related musculoskeletal disorders (WMSDs). ObjectiveTo analyze work posture and associated muscle fatigue during executing breaking/connecting contact terminal, and identify adverse ergonomic factors of the work process. MethodsThis study recruited 10 volunteers to perform breaking/connecting contact terminal simulation. At a distance of 4.5, 3.5, and 2.5 m from the body to the wire, each performed the task 5 times. Visual 3D was used to analyze the kinematic data from motion capture. The surface electromyography (sEMG) signals of the deltoid, biceps, triceps, and brachioradialis were recorded during the simulation and analyzed for muscle fatigue using root mean square (RMS), median frequency (MF), and jointed EMG amplitude and spectrum analysis (JASA). After completion of each task, Borg scale was used to query the volunteers of their subjective fatigue. A 2-min rest was required between each distance. ResultsThe kinematic data from motion capture showed that in the entire process of the task, the right upper limb was higher when lifting, with the right shoulder joint maintaining flexion and fluctuating periodically between abduction and adduction, external and internal rotation, the right elbow joint maintaining flexion and supination. The frequency of task cycle showed a significant effect on the Borg scale scores (P<0.001, partial \begin{document}$ {\eta }^{2} $\end{document}=0.464); the distance showed no significant effect on the Borg scale scores (P>0.05, partial \begin{document}$ {\eta }^{2} $\end{document}=0.002); their interaction effect was not significant (P>0.05, partial \begin{document}$ {\eta }^{2} $\end{document}=0.020). The results of the sEMG signals showed that at a distance of 4.5 m, the volunteers had the highest percentages of maximal voluntary electrical activation (MVE%) in the deltoid and right brachioradialis and the lowest MF values in the deltoid and left brachioradialis after completing 5 task cycles. The results of JASA showed that fatigue was observed in brachioradialis and deltoid after completing 5 task cycles at a distance of 4.5 m, the right deltoid and right brachioradialis at a distance of 3.5 m, in the brachioradialis, deltoid, and left bicep at a distance of 2.5 m. ConclusionThe subjective fatigue of workers who engaged in breaking/connecting contact terminal elevates with more repetitive operations. Based on the sEMG and motion capture analysis, it can be found that improper distance between the workers and the target work area can increase the burden from poor posture and improper use of work equipment, and lead to muscle fatigue; the deltoid and brachioradialis are the key muscles of fatigue in this type of operation; changing the angle of the elbow joint and the shoulder joint during the process of the operation can affect the deltoid and brachioradialis exertion and loading.

SHILAP Revista de lepidopterología
Guangxi Hydraulic Power Machinery Research Institute (CN), Guangxi Special Equipment Inspection Institute (CN), China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
Decent work and economic growth
Openalex Percentile: Top 53%
Musculoskeletal pain and rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.