Single-FrequencyEffective Capacitance <i>C</i><sub>ec</sub> and MembraneResistance <i>Z</i> Readoutfor Solid-Contact Ion-Selective Electrodes

Here, we propose new single-frequency effective capacitance <i>C</i><sub>ec</sub> and membrane resistance <i>Z</i> readout principle for solid-contact ion-selective electrodes (SCISEs). Conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) doped with polystyrenesulfonate (PSS<sup>–</sup>), <i>i.e.</i>, PEDOT(PSS), as solid contact and valinomycin-based membrane were prepared for K<sup>+</sup>-SCISEs. At high frequencies, the membrane resistance of K<sup>+</sup>-SCISEs corresponding to impedance absolute value <i>Z</i> was recorded constantly as KCl aqueous solution diluted with water. The membrane resistance <i>Z</i> increases as the electrolyte concentration decreases. Under identical dilution steps, the linear slope of the logarithmic membrane resistance log<i>Z</i> <i>vs</i> log<i>a</i><sub>K+</sub> for K<sup>+</sup>-SCISEs with the spin-coated membrane is larger than that of the electrode covered with the drop-cast membrane. As the K<sup>+</sup>-SCISE resistance with the spin-coated membrane was reduced to hundreds of Ω, the log<i>Z</i> of K<sup>+</sup>-SCISEs is linearly proportional to log<i>a</i><sub>K+</sub> in the range of −1 to −3.4, providing a possibility of utilizing membrane resistance <i>Z</i> as a calibration-free analytical signal for SCISEs. The effective capacitance <i>C</i><sub>ec</sub> of K<sup>+</sup>-SCISEs with the spin-coated membrane was performed in 0.1 M KCl applied with single frequency ranging from 1 MHz and decreases by a factor of 10 to 10 mHz. The obtained <i>C</i><sub>ec</sub> of K<sup>+</sup>-SCISEs with the spin-coated membrane is linearly proportional to log<i>f</i>in the range of 1 MHz to 10 Hz with a slope of <i>ca.</i> −0.97, while at a low frequency ranging from 1 Hz to 10 mHz, the linear slope of log<i>C</i><sub>ec</sub> <i>vs</i> log<i>f</i> is suppressed, where Warburg diffusion takes effect. Furthermore, the membrane resistance <i>Z</i> is independent of applied high frequencies, and the effective capacitance <i>C</i><sub>ec</sub> is independent of the excitation amplitude.

Publication Details

Journal
Figshare
Published
2025-03-13
DOI
https://doi.org/10.1021/acsmeasuresciau.4c00093.s001
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Single-FrequencyEffective Capacitance Cec and MembraneResistance Z Readoutfor Solid-Contact Ion-Selective Electrodes

Figshare
Analytical Chemistry and Sensors
article

Single-FrequencyEffective Capacitance Cec and MembraneResistance Z Readoutfor Solid-Contact Ion-Selective Electrodes

article en

Abstract

Here, we propose new single-frequency effective capacitance <i>C</i><sub>ec</sub> and membrane resistance <i>Z</i> readout principle for solid-contact ion-selective electrodes (SCISEs). Conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) doped with polystyrenesulfonate (PSS<sup>–</sup>), <i>i.e.</i>, PEDOT(PSS), as solid contact and valinomycin-based membrane were prepared for K<sup>+</sup>-SCISEs. At high frequencies, the membrane resistance of K<sup>+</sup>-SCISEs corresponding to impedance absolute value <i>Z</i> was recorded constantly as KCl aqueous solution diluted with water. The membrane resistance <i>Z</i> increases as the electrolyte concentration decreases. Under identical dilution steps, the linear slope of the logarithmic membrane resistance log<i>Z</i> <i>vs</i> log<i>a</i><sub>K+</sub> for K<sup>+</sup>-SCISEs with the spin-coated membrane is larger than that of the electrode covered with the drop-cast membrane. As the K<sup>+</sup>-SCISE resistance with the spin-coated membrane was reduced to hundreds of Ω, the log<i>Z</i> of K<sup>+</sup>-SCISEs is linearly proportional to log<i>a</i><sub>K+</sub> in the range of −1 to −3.4, providing a possibility of utilizing membrane resistance <i>Z</i> as a calibration-free analytical signal for SCISEs. The effective capacitance <i>C</i><sub>ec</sub> of K<sup>+</sup>-SCISEs with the spin-coated membrane was performed in 0.1 M KCl applied with single frequency ranging from 1 MHz and decreases by a factor of 10 to 10 mHz. The obtained <i>C</i><sub>ec</sub> of K<sup>+</sup>-SCISEs with the spin-coated membrane is linearly proportional to log<i>f</i>in the range of 1 MHz to 10 Hz with a slope of <i>ca.</i> −0.97, while at a low frequency ranging from 1 Hz to 10 mHz, the linear slope of log<i>C</i><sub>ec</sub> <i>vs</i> log<i>f</i> is suppressed, where Warburg diffusion takes effect. Furthermore, the membrane resistance <i>Z</i> is independent of applied high frequencies, and the effective capacitance <i>C</i><sub>ec</sub> is independent of the excitation amplitude.

Figshare
Clean water and sanitation
Openalex Percentile: Top 52%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Single-FrequencyEffective Capacitance <i>C</i><sub>ec</sub> and MembraneResistance <i>Z</i> Readoutfor Solid-Contact Ion-Selective Electrodes · Figshare (2025) | TGRS Research Map | TGRS